2.4 SYSTEM USE.

Before ignition, make sure the system is full of
water, checking that the pressure gauge needle
(6) points to a value between 1 and 1.2 bar and
make sure that the chiller circuit has been filled
as described in the condensing unit instructions
booklet.
- Press the button (1) until the display switches
on. The system now goes back to the state prior
to switch-off.
- If the hydronic module is in stand-by, press the
button (1) again to activate it. Otherwise, go to
the next point.
- Then press the button (1) in sequence and set
the system to summer (
), winter (
heating/air conditioning (
) position.
• Summer (
): in this mode, the system only
works to produce domestic hot water, the
temperature is set using the buttons (4) and
the corresponding temperature is shown on
the display by the indicator (14).
Summer and DHW heating in
progress mode
• Winter (
): in this mode, the system works
both to product domestic how water and room
central heating. The temperature of the DHW
is always regulated via buttons (4), the central
heating temperature is regulated via buttons
(5) and the relative temperature is shown on
the display by the indicator (14).
Winter and room central heating in
progress mode
• Heating/air conditioning (
): in this mode,
the system works both to produce DHW and to
cool the room. The temperature of the DHW
is always regulated via buttons (4), the cooling
temperature is regulated via buttons (6) and the
relative temperature is shown on the display by
the indicator (14).
Heating/Air conditioning and room
cooling in progress mode
From here on, the system works automatically.
) or
If there are no requests (room central heating,
DHW production or cooling), the system goes
into the "stand-by" function. Each time the
condensing unit ignites, the display shows the
corresponding symbol (8) with the correspond-
ing power scale (10).
• Operation with Comando Amico Remoto
(CAR
) (Optional). If the CAR
V2
the (
) symbol will appear on the display.
The system regulation parameters can be set via
the CAR
control panel and the reset button
V2
(3) remains active on the hydronic module
control panel, along with the switch-off button
(1) ("off " mode only) and the display showing
the functioning state.
The system is set up to manage two CAR
The CAR
connected to the main zone (zone
V2
2 or low temperature) is considered as the
hydronic module mount panel, while the
CAR
connected to the secondary zone (zone
V2
2-2
1 or high temperature) manages the requests
in the corresponding zone. Consequently, the
"secondary" CAR
is not to be considered as
V2
the hydronic module mount panel.
Attention: if the hydronic module is switched
"off " the CAR
will display the connection
V2
error symbol "ERR>CM". The CAR
powered constantly so as not to lose the saved
programs.
•Operation with external probe (
system is set up to use the condensing unit
external probe or an optional external probe.
With the external probe connected, the system
flow temperature for room heating and air
conditioning is managed by the external probe
based on the outdoor temperature measured
(Parag. 1.9). You can change the flow tempera-
ture by choosing the offset value in the specific
user menu. If the CAR
change the operating curve using the controls
on it, selecting a value from "0 to 9" (See CAR
instructions). In this case, any settings made
2-3
on the hydronic module will not affect system
operation.
• Dehumidify (
). If the system is paired with
a humidistat (optional) or a humidity temper-
ature sensor (optional), you can manage the
15
room humidity in summer air conditioning
mode.
- If paired with a humidistat, set the degree
of humidity on the humidistat itself (see the
instructions booklet).
- If paired with a humidity temperature sensor,
set the humidity percentage in the corre-
sponding user menu or, if there is a CAR
you can set it on the remote control itself from
the "S UR %" parameter.
2-4
V2
Heating/Air conditioning and
is connected,
V2
Dehumidification active mode
• In central heating or cooling request mode,
if the temperature of the water in the system
meets the request, the system can work simply
by activating the circulator.
• "Stand-by" mode. Press button (1) repeatedly
.
V2
until the symbol (
the system remains inactive and the antifreeze
function, pump anti-block function and 3-way
and signalling of any anomalies is guaranteed.
N.B.: in these conditions the system must still
be considered powered.
• "Off " mode. By holding the button (1) down
for 8 seconds, the display switches off and the
hydronic module is completely off. The safety
functions are not guaranteed in this mode.
is still
N.B.: in these conditions, the hydronic module
V2
must still be considered powered even if there
are no functions active.
• "Automatic vent" mode. Every time the
). The
hydronic module is electrically powered, the
system automatic vent function is activated
(lasting 8 minutes). This function is displayed
via a countdown signalled by the indicator (14).
During this period the DHW and CH functions
are not active.
The "automatic vent" can be annulled by press-
ing the "reset" button (3).
is connected, you can
V2
• Display operation. The display lights up while
the control panel is being used; after a set in-
V2
activity period, the brightness drops until only
the active symbols are displayed. The lighting
mode can be varied via parameter t8 in the
P.C.B. programming menu.
,