Use And Maintenance Instructions; Cleaning And Maintenance; General Warnings; Control Panel - Immergas MAGIS PRO ERP Instruction And Recommendation Booklet

Mono-phase hydronic module to pair with an outdoor condensing unit
Table of Contents

Advertisement

2
USE AND MAINTENANCE
INSTRUCTIONS

2.1 CLEANING AND MAINTENANCE.

Attention: to preserve system integrity and keep
the distinguishing safety features, performance
and reliability unchanged over time, you must
execute maintenance operations at least on a
yearly basis in compliance with what is stated in
the point regarding "annual appliance check and
maintenance". Annual maintenance is essential to
validate the conventional warranty of Immergas.
We recommend stipulating a yearly cleaning and
maintenance contract with your zone Immergas
Authorised After-sales Service.

2.2 GENERAL WARNINGS.

Do not expose the hydronic module to direct
steam from cooking surfaces.
Children and unskilled persons are not allowed
to use the hydronic module.
Should you decide to temporarily shut down the
hydronic module, you must:
a) drain the heating system if antifreeze is not
used;
b) shut off the electrical and water supply.
Never clean the appliance or connected parts
with easily flammable substances.
Never leave containers or flammable substances
in the same environment as the appliance.
• Attention: using any components that use
electrical power requires some fundamental
rules to be observed:

2.3 CONTROL PANEL.

2-1
ESC
Key:
1 - Operating mode (winter - heating/air
conditioning - summer - stand-by - off)
and parameter confirm button
2 - Menu selection button
3 - Reset and exit menu button
4 - Domestic hot water temperature selec-
tion buttons
5 - Heating system temperature selection
buttons
6 - Hydronic module pressure gauge
7 - Remote control connection (optional)
8 - Condensing unit operation in progress
- do not touch the appliance with wet or moist
parts of the body; do not touch when bare-
foot;
- never pull electrical cables or leave the appli-
ance exposed to weathering (rain, sunlight,
etc.);
- the appliance power cable must not be re-
placed by the user;
- in the event of damage to the cable, switch
off the appliance and contact exclusively
qualified staff for replacement;
- if the appliance is not to be used for a certain
period, disconnect the main power switch.
N.B.: the temperatures shown on the display
have a tolerance of +/- 3°C due to environmen-
tal conditions that cannot be attributed to the
hydronic module.
At the end of its service life, the appliance must
not be disposed of like normal household waste
nor abandoned in the environment, but must
be removed by a professionally authorised
company. Contact the manufacturer for disposal
instructions.
bar
OK
9 - Not used
10 - Dispensed output level
11 - Operation with external temperature
probe active (optional)
12 - Connection to other Immergas units
13 - Room central heating mode active
14 - Temperature indicator, hydronic module
info and error codes
15 - Room cooling mode operation active
16 - Operation in cooling mode
17 - Operation in winter mode
18 - Operation in summer mode
19 - Stand-by mode
20 - Not used
21 - Hydronic module locked, requiring
22 - Operation in dehumidification mode
23 - DHW production phase operating mode
14
release by "RESET" button
active