Installer
To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE
NSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION
FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES.
After installation, leave these instructions inside the fountain for future reference.
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO
WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY
OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO
A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE
IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER
MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE
OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.
EHFRA7C*A EHFRA7FC*A
Fully Recessed Refrigerated
Fountain with FLEXI-GUARD
12, 13
21
14
IMPORTANT
IMPORTANT! INSTALLER PLEASE NOTE.
9
SEE FIG. 5
SEE FIG. 9
Page 1
®
97160C (Rev. D - 10/16)

Advertisement

loading

Summary of Contents for Elkay FLEXI-GUARD EHFRA7C A Series

  • Page 1 EHFRA7C*A EHFRA7FC*A Installation/Care/Use Manual Fully Recessed Refrigerated Fountain with FLEXI-GUARD ® 12, 13 SEE FIG. 5 SEE FIG. 9 Installer To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE NSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES.
  • Page 2 EHFRA7C*A EHFRA7FC*A EHFRA7C ROUGH-IN FINISHED FLOOR LINE FINISHED FLOOR FIG. 1 LEGEND: A = RECOMMENDED WATER SUPPLY LOCATION 3/8" O.D. UNPLATED COPPER TUBE CONNECT STUB 1-1/2" (38mm) OUT FROM WALL, SHUT OFF BY OTHERS (BOTH SIDES). B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4" O.D. DRAIN (BOTH SIDES). C = 1-1/4"...
  • Page 3: Installation Instructions

    EHFRA7C*A EHFRA7FC*A Note: Danger! Electric shock hazard. Disconnect power before servicing unit. INSTALLATION INSTRUCTIONS 1. Remove shipping brace from mounting box and discard. 2. Fasten mounting box into wall cutout using screws or bolts (provided by others) through holes or knockouts provided on each side of the mounting box.
  • Page 4 SEE FIG. 5 FIG. 8 WASTE ARM ASSY FIG. 9 FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.834.4816 ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484 97160C (Rev. D - 10/16) Page 4...

This manual is also suitable for:

Flexi-guard ehfra7fc a series