Frequency: The AC output frequency
P_OK: xxx of yyy: There is a connection to the power optimizers and at least one
power optimizer is sending monitoring data. XXX is the number of power optimizers
for which telemetries have been received in the last two hours. YYY is the number
of paired power optimizers identified during the most recent pairing process. If XXX
and YYY are not equal, there may be a problem in one or more power optimizers.
S_OK: The connection to the monitoring platform. (Server Connected appears only
if the inverter is connected to the monitoring platform).
Status: The inverter operation status: Off, Not Paired, Night Mode, Error, Pairing, or
Production.
Switch: Indicates the position of the inverter ON/OFF/P switch: On, Off, or P
position.
CosPhi: Indicates the ratio between active and reactive power.A negative value
indicates a lagging CosPhi.
For more information, refer to the Power Control Application
Note , available on the SolarEdge website at
https://www.solaredge.com/sites/default/files/application_note_
power_control_configuration.pdf.
Limit: The inverter maximum output power
Country: The selected country and grid setting
Voltage (Vdc): The DC input voltage
Temp (°C or °F): The inverter heat sink temperature
 