Download Print this page
Elkay EMASM Installation And Use Manual

Elkay EMASM Installation And Use Manual

Surface mount bottle filling station

Advertisement

Quick Links

Installation and Use Manual
EMASM Surface Mount Bottle Filling Station
Installer
To assure you install this model easily and correctly, PLEASE READ THESE
SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK
YOUR INSTALLATION FOR COMPLIANCE WITH ALL PLUMBING, ELECTRICAL
AND OTHER APPLICABLE CODES. FOLLOW ALL WARNINGS AND CAUTIONS
CAREFULLY. After installation, leave these instructions with the customer for future
reference.
Warnings
1. Use with clean, clear, fresh potable drinking water only! Do not use with water that is microbiologically
unsafe or of unknown quality without adequate disinfection before the system.
2.
These products are designed to operate on 20 to 105 PSI supply line pressure. If inlet pressure
is above 105 PSI, a pressure regulator must be installed in supply line. Any damage caused by
reason of connecting this product to supply line pressure lower than 20 PSI or higher than
105 PSI is not covered by warranty
EMASM*A
THIS IS AN INDOOR APPLICATION ONLY!
ALL SERVICE TO BE PERFORMED BY AN
.
Page 1
IMPORTANT
AUTHORIZED SERVICE PERSONNEL.
TOOLS/ITEMS REQUIRED
BUT NOT SUPPLIED
- SERVICE STOP VALVE WITH 3/8"
COMPRESSION OUTLET
- FASTENERS FOR WALL TYPE (8 REQ'D.)
- SLIP JOINT DRAIN UNION OR
COMPRESSION CLAMP
- 5/32" HEX-WRENCH
0000001496 (Rev. F - 08/17)

Advertisement

loading

Summary of Contents for Elkay EMASM

  • Page 1 EMASM*A Installation and Use Manual EMASM Surface Mount Bottle Filling Station IMPORTANT THIS IS AN INDOOR APPLICATION ONLY! ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSONNEL. TOOLS/ITEMS REQUIRED BUT NOT SUPPLIED - SERVICE STOP VALVE WITH 3/8" COMPRESSION OUTLET - FASTENERS FOR WALL TYPE (8 REQ’D.)
  • Page 2: Installation Notes

    EMASM*A ROUGH-IN EMASM ADA STAND-ALONE MOUNTING IMPORTANT! INSTALLATION NOTES: • Ensure wall is structurally sound to bear the loads imparted by the Surface Mount Bottle Filler. • Ambient air temperature limits: 10°C - 38°C (50°F - 100.4°F). Climate Class SN-ST.
  • Page 3 EMASM*A ROUGH-IN EMASM ADA ABOVE COOLER MOUNTING IMPORTANT! INSTALLATION NOTES: • Ensure wall is structurally sound to bear the loads imparted by the Surface Mount Bottle Filler. • Ambient air temperature limits: 10°C - 38°C (50°F - 100.4°F). Climate Class SN-ST.
  • Page 4: Installation Instructions

    INSTALLATION INSTRUCTIONS Pre-Installation (reference Rough-In, Fig. 1 and Fig. 3) 1. Ensure Wall is structurally sound to bear the loads imparted by the EMASM Bottle Filler (On-Wall Bottle Filler). If necessary, install a Wall Support Carrier (not supplied). 2. Ensure Water Supply Line and Drain Line are sized and located as specified the Rough-in diagram.
  • Page 5: Replacement Parts

    FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.834.4816 PRINTED IN U.S.A. REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640 ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484 • www.elkay.com 0000001496 (Rev. F - 08/17) Page 5...