Immergas ARES PRO 150 Instructions And Recommendations page 47

High condensate water storage generator
Table of Contents

Advertisement

SPEED OUT OF CONTROL
26
Fan speed alteration; the speed is higher than
what is requested.
NO AIR
27
Stop
DEFAULT PARAMETERS
30
Alteration of default settings or any electro-
magnetic interferences.
Line voltage below 80% of the nominal value.
32
Wait for the line's voltage to reach > 85% of
the nominal value.
DESCRIPTION obtained from HCM
CODE
MINIMUM GAS PRESSURE SWITCH
2
INTERVENTION
stop effect
HEAT EXCHANGER FREEZING (24) stop
17
effect
MAXIMUM PROTECTION ∆T FLOW-RE-
18
TURN
stop effect
FLOW OVERHEATING.
It is activated when the flow temperature is
19
> 95. It is automatically restored when the
temperature is < 80.
Effect: Stop burner, Pump on
CLOGGED DRAINS
28
Stop
WATER IN THE COMBUSTION CHAM-
29
BER
Stop
DEFECTIVE PARAMETERS
37
MEMORY
Flame Block
DEFAULT PARAMETERS CORRUPTED
38
by electromagnetic interferences
stop
FL INTERVENTION insufficient water
40
circulation Stop
REMOTE CONTROL WAS NOT DETECT-
56
ED
Flame Block
BMM BOARD NOT DETECTED
57
stop
FLOW SENSOR
58
Stop
ISPESL SAFETY INTERVENTION
93
Stop
The error codes are displayed in the info row of the remote panel and
also remain if the fault was temporary.
Therefore, you must always reset to eliminate the "Allarm" from the
display.
Check operation of the fan (18) and the connections
Check that the fan has minimum head of 60 Pa.
Press the release key, if the fault persists, replace the board
Correction: if the line voltage < 190Vac: the line's voltage is way below the mini-
mum limit, otherwise line errors of the monitor: replace BMM
(BCM)
The ignition procedure is prevented until the gas pressure has reached the correct
values.
Try to Reset for the system to automatically activate the antifreeze function and
thus may only be a warning.
Circulation control, check installation (Only with return probe installed).
Circulation control.
Check Chimneys / Check Drain Trap.
Check the combustion chamber / check the drain trap.
Contact support service.
Contact support service.
Water circulation control
Check electrical connections e-BUS1
Check electrical connections BMM e-BUS1
Connect a new sensor if the code disappears, replace the sensor or check the
electrical connections
Check the safety devices, manual reset after releasing single safety devices
Inspections and maintenance
REMEDIES
47