Health O Meter  522KL User Instructions
Health O Meter  522KL User Instructions

Health O Meter 522KL User Instructions

Digital pediatric tray scale
Hide thumbs Also See for Health O Meter 522KL:

Advertisement

Model 522KL / 522KG
Digital Pediatric Tray Scale

User Instructions

E112697
UL 60601-1
CSA C22.2 No. 601.1-M90
PELSTAR, LLC
9500 West 55th St. McCook, IL 60525-7110 USA
www.homscales.com
®
Health o meter
Professional 522KL
®
Health o meter
Professional 522KG
© Pelstar, LLC 2019
1
P/N UM522KL_522KG Rev20190412

Advertisement

Table of Contents
loading

Summary of Contents for Health O Meter Health O Meter 522KL

  • Page 1: User Instructions

    Digital Pediatric Tray Scale User Instructions E112697 UL 60601-1 CSA C22.2 No. 601.1-M90 PELSTAR, LLC 9500 West 55th St. McCook, IL 60525-7110 USA www.homscales.com ® Health o meter Professional 522KL ® Health o meter Professional 522KG © Pelstar, LLC 2019 P/N UM522KL_522KG Rev20190412...
  • Page 2: Table Of Contents

    Professional 522KL ® Health o meter Professional 522KG ® Thank you for purchasing this Health o meter Professional product. Please read this manual carefully, and keep it for easy reference or training. TABLE OF CONTENTS Cautions and Warnings ..................... 3 Specifications ......................
  • Page 3: Cautions And Warnings

    When operating the scale with the (optional) AC adapter:  Operate this scale exclusively with the AC adapter provided by Health o meter Professional. Use of an unspecified adapter will void the warranty, and can pose a serious safety hazard.
  • Page 4: Specifications

    SPECIFICATIONS General ® The Health o meter Professional 522KL/522KG scale uses highly sophisticated microprocessor technology. Each precision scale is designed to provide accurate, reliable and repeatable weight measurements. In addition, each scale is designed to provide the user with features that make the weighing process simple, fast, and convenient.
  • Page 5: Certifications / Connectivity / Disposal

    For reliable transmission of weight data, this scale is designed to connect to a computer, ® monitor, or other electronic data device via Health o meter Professional Connectivity Solutions. This connectivity helps minimize transcription errors when recording patient data. For further information regarding how to connect this scale to other electronic devices, please contact ®...
  • Page 6: Assembly Instructions

    Carefully inspect the carton for shipping damage before unpacking. If damage is found, contact ® your shipper or a Health o meter Professional representative immediately at 1-800-815-6615. Claims must be filed with the shipper as soon as possible after receipt of the package. The following information details what you will find inside the main carton as you unpack the parts for assembly.
  • Page 7 ASSEMBLY INSTRUCTIONS (CONTINUED) 1. Carefully remove the contents Screws and washers of the carton and place each part on a flat, level, and dry surface. Remove the 4 column mounting screws and washers from the bottom of column and set aside for assembly step 5. 2.
  • Page 8 ASSEMBLY INSTRUCTIONS (CONTINUED) 5. Position and secure the column to the scale platform. Locate the 4 column mounting screws previously removed in step 1. Insert the 4 screws through the bottom of the scale platform screw holes and into the column. Ensure that washers are located between the screw heads and the scale platform screw holes.
  • Page 9: Powering The Scale

    1. Connect the AC adapter (not included) into the adapter jack on the scale platform. ® Warning: To avoid a safety hazard, use only a Health o meter Professional AC adapter. 2. Plug the scale’s AC adapter into the power source/wall outlet. Caution: Always plug the AC adapter into the scale first, then into the power source/wall outlet.
  • Page 10: Operating Instructions

    OPERATING INSTRUCTIONS Auto-Off Function As an energy saving feature, the scale will automatically turn off after 2 minutes of inactivity. By default, this function is enabled. Note: The Auto-off function is only active when the scale is being powered by batteries. Note: The scale will not power off if a weight is held on the display. Disable Auto-Off 1.
  • Page 11 OPERATING INSTRUCTIONS (CONTINUED) Weighing a Patient 1. Make sure there is nothing on the tray. 2. Press the ON/OFF button to turn the display assembly on. “88:8:8.8” followed by “0:0.0” will appear on the display. 3. Lay the baby on the scale so that its weight is evenly distributed on the tray. The scale will begin to display weight information and will lock on the patient’s weight when the stable weight of the patient is determined.
  • Page 12: Maintenance And Cleaning

    Caution: Disconnect the scale from the AC adapter power source prior to cleaning the unit. ® 1. Health o meter Professional recommends using one of the following solutions on a soft cloth or disposable wipe: ● mild soap and water solution ●...
  • Page 13: Calibration

    CALIBRATION This scale has been factory calibrated, and does not require calibration prior to use. If required, the scale can be calibrated. Calibration of your scale must be performed using kilograms (KG). 20 kilograms are required for calibration, applied in 5 kg increments.
  • Page 14: Troubleshooting

    TROUBLESHOOTING Troubleshooting Before contacting service personnel, refer to the following instructions to check and to correct any failures. Symptom Possible Cause Corrective Action Scale does not turn on 1. Dead battery 1. Replace batteries 2. Faulty electrical outlet 2. Use a different outlet 3.
  • Page 15: Warranty

    ® Health o meter Professional products are manufactured, designed, and owned by Pelstar, LLC. ® We reserve the right to improve, enhance, or modify Health o meter Professional product features or specifications without notice. © Pelstar, LLC 2019 P/N UM522KL_522KG Rev20190412...