Top View - State Water Heaters SUF-130- 300/400/500 Instruction Manual

State water heaters water heater user manual
Table of Contents

Advertisement

top View

top View components
1. Water Heater's 120 VAC on/off switch.
2. Powered anode rods. The water heater's covered in this
manual are equipped with two powered (non sacrificial)
anode rods. Protective current is fed by the control system
to the titanium electrodes at the end of each anode rod. This
current flows through the water to the conductive surfaces
inside the storage tank which diminishes the corrosive effect
(rusting) of water when it comes in contact with steel.
3. Central Control Board (CCB) enclosure. This enclosure
houses the control system's main circuit board. The CCB
regulates water temperature and controls all water heater
functions, see Control System Operation on page 8.
4. 120 VAC junction box. incoming power supply and ground
connections are made here. See Power Supply on page 8.
5. intake air connection - 4 inch PVC.
6. Blocked intake Air switch. Normally closed contacts that
open on fall in pressure. This switch is used to insure intake
(combustion) air to the water heater is not restricted. The
control system monitors this switch and will disable heating
operation if its contacts are open during a heating cycle.
7. Water heater's 24 VAC Gas Valve.
8. Supply gas line connection. See the requirements for the
Supply Gas Line on page 8.
9. Low Gas Pressure switch. Normally open contacts that close
on a rise in pressure. This switch is used to insure supply
gas pressure is above minimum requirements. The control
system monitors this switch and will disable heating operation
if its contacts are open during a heating cycle. See Table 4
and the Gas Pressure requirements on page 8.
10. Blower Prover switch. Normally open contacts that close on a
6
5
4
3
2
1
7
8
9
10
11
FRONT
16
17
18
figure 3
rise in pressure. This switch is used to insure the Combustion
Blower is operating properly. The control system monitors
this switch and will disable heating operation if its contacts
are closed before the Combustion Blower is energized or
open any time during a heating cycle. See Sequence Of
Operation on page 8.
11. Vent connection (exhaust elbow) - 4 inch PVC.
12. Combustion Blower.
13. Blocked Exhaust (vent) switch. Normally closed contacts that
open on a rise in pressure. This switch is used to insure the
Exhaust (vent) piping connected to the water heater is not
restricted. The control system monitors this switch and will
disable heating operation if its contacts are open during a
heating cycle.
14. VFD (variable frequency drive) blower motor drive. Used on
SUF 130 400 and SUF 130 500 models only.
15. Temperature-Pressure relief Valve. See Temperature-
Pressure relief Valve on page 8.
16. Upper Temperature Probe, 1 of 2 temperature probes. The
water heater's control system monitors this probe to detect
water temperature in the upper portion of the storage tank.
The Upper Temperature Probe also houses the ECO (energy
cut out) switch. This is a non adjustable high temperature
limit switch. The ECO switch contacts are normally closed
and will open on a temperature rise. See High Temperature
Limit Control (ECO) on page 8.
17. Water outlet connection 1 1/2" NPT.
18. Uim (user interface module). The Uim includes the display circuit
board, the control system's LCD display and operational buttons.
Used to adjust various user settings and view operational
information. See Control System Operation on page 8.
8
12
13
2
14
15

Hide quick links: