1.11 SEPARATOR KIT INSTALLATION.

Type C configuration, sealed chamber and
fan assisted.
This kit allows air to come in from outside the
building and the fumes to exit from the chim-
ney or flue through divided flue exhaust and air
intake pipes. Combustion products are expelled
from pipe (S). The required amount of air is taken
in through pipe (A) for combustion. Both ducts
can be routed in any direction.
Separator kit Ø 80/80. Kit assembly (Fig. 12):
install the flange (4) on the central hole of the
water heater, interposing the gasket (1) and
tighten with the flat-tipped hex screws included
in the kit. Remove the flat flange present in the
lateral hole with respect to the central one (ac-
cording to needs) and replace it with the flange
(3), positioning the gasket (2) already present on
the water heater and tighten using the supplied
self-threading screws.
S
7
9
4
1
The kit includes:
N°1 - Exhaust gasket (1)
N°1 - Flange gasket (2)
12
N°1 - Female intake flange (3)
14
Attention: if the installation requires a significant
development of the flue to the discharge, due
consideration must be given to the formation of
Fit the male side (smooth) to the bends (5) in
the female side of the flanges (3 and 4). Fit the
intake terminal (6) with the male side (smooth)
in the female side of the bend (5) up to the end
stop, ensuring that the internal and external wall
sealing plates are fitted. Fit the exhaust pipe (9)
with the male end (smooth) in the female end of
the bend (5) up to the stop, making sure that the
internal wall sealing plate has been fitted, this will
ensure sealing and joining of the kit elements.
• Installation clearances (Fig. 13). The minimum
installation clearance measurements of the Ø
80/80 separator terminal kit have been stated
in one limit condition.
• The figure (Fig. 14) shows the configuration
with vertical exhaust and horizontal intake.
• Extensions for separator kit Ø 80/80. The
maximum vertical rectilinear length (without
bends) used for Ø80 intake and exhaust pipes
can be calculated by using the graphs for ducts
with different lengths on page 8.
5
5
A
6
3
7
2
N°1 - Female exhaust flange (4)
N°2 - 90° bend Ø 80 (5)
N°1 - Intake terminal Ø 80 (6)
N°2 - Internal wall sealing plates (7)
N°1 - External wall sealing plate (8)
C
52
N°1 - Exhaust pipe Ø 80 (9)
To calculate the intake "L Ø80 A" and exhaust "L Ø80 S" distance, refer to the graph on page
8 regarding separate ducts having different lengths.
condensate that could take place inside the pipe
and Immergas insulated "Blue Series" flue kits
must be used.
C
82
8
L Ø80 A
11
C
42
13
C
82
L Ø80 S
15