Concentric Horizontal Kit Installation; Concentric Vertical Kit Installation - Immergas CAESAR ECO 11 Instructions And Warnings

Wall-hung instantaneous water heaters
Hide thumbs Also See for CAESAR ECO 11:
Table of Contents

Advertisement

1.9 CONCENTRIC HORIZONTAL KIT
INSTALLATION.
Type C configuration, sealed chamber and
fan assisted.
Installation of this terminal is governed by cur-
rent technical regulations.
This terminal is connected directly to the outside
of the building for air intake and flue exhaust. The
horizontal kit can be installed with the rear, right
side, left side or front outlet.
• External grid. The Ø 60/100 intake/exhaust
terminal, if properly installed, is pleasant to
look at on the outside of the building. Make
sure that the external silicone wall sealing plate
is properly inserted in the wall.
Horizontal intake-exhaust kit Ø 60/100. Kit
assembly (Fig. 8): install the bend with flange
(2) onto the central hole of the water heater
inserting the gasket (1) and tighten using the
screws included in the kit. Couple the concentric
terminal pipe Ø 60/100 (3) with the male end
(smooth) into the female end (with lip seals)
of the bend (2) up to the stop, making sure that
the internal and external wall sealing plate have
been fitted, this will ensure sealing and joining
of the kit elements.
2
1
3
The kit includes:
N° 1 - Gasket (1)
N° 1 - Concentric bend Ø 60/100 (2)
N° 1 - Int./exhaust concentric terminal Ø 60/100 (3)
N° 1 - Internal wall sealing plate (4)
N° 1 - External wall sealing plate (5)
7
6
5
4
3
2
1
• Extensions for Ø 60/100 horizontal kit
(Fig. 9). The kit with this configuration can be
extended up to a max. horizontal length of 5.7 m
(for Caesar Eco 11) and horizontal length of 3.7
m (for Caesar Eco 14), including the terminal
with grid and excluding the concentric bend
leaving the water heater. In this case the special
extensions must be requested.
1.10 CONCENTRIC VERTICAL KIT
INSTALLATION.
Type C configuration, sealed chamber and
fan assisted.
Concentric vertical intake and exhaust kit. This
vertical terminal is connected directly to the out-
side of the building for air intake and flue exhaust.
N.B.: the vertical kit with aluminium tile enables
installation on terraces and roofs with a maxi-
mum slope of 45% (approx 25°) and the height
between the terminal cap and half-shell (374
mm) must always be respected.
C
12
4
5
8
C
32
The fixing plate kit includes:
N° 1 - Gasket (1)
N° 1 - Female concentric
flange (2)
The Kit includes:
N° 1 - Concentric intake-
exhaust pipe
Ø 60/100 (3)
N° 1 - Wall sealing plate (4)
N° 1 - Aluminium tile (5)
N° 1 - Fixed half-shell (6)
N° 1 - Mobile half-shell (7)
10
Vertical kit with aluminium tile Ø 60/100.
To use this kit one must use the fixing plate kit
60/100 (sold separately).
Kit assembly (Fig. 10): install the concentric
flange (2) on the central hole of the water heater
inserting the gasket (1) and tighten using the
screws in the kit. Fit the male end (smooth) of the
adapter (3) into the female end of the concentric
flange (2). Imitation aluminium tile installation.
Replace the tile with the aluminium sheet (5),
shaping it to ensure that rainwater runs off.
Position the fixed half-shell (7) and insert the in-
take-exhaust pipe (6). Fit the Ø 80/125 concentric
terminal pipe with the male end (6) (smooth) to
the female end of the adapter (3) (with lip gasket)
up to the stop; making sure that the wall sealing
plate (4) has been fitted, this will ensure sealing
and joining of the elements making up the kit.
•Extensions for vertical kit Ø 60/100 (Fig. 11).
The kit with this configuration can be extended
up to maximum 6.7 vertical rectilinear metres
(for Caesar Eco 11) and 4.7 vertical rectilinear
metres (for Caesar Eco 14), including the
terminal. This configuration corresponds to
a resistance factor of 100. In this case specific
extensions must be requested.
MAXIMUM EQUIVALENT LENGTH 5700 (CAESAR ECO 11)
MAXIMUM EQUIVALENT LENGTH 3700 (CAESAR ECO 14)
N.B.: to calculate the equivalent lengths, refer to the table on page 8.
10
N.B.: to calculate the equivalent lengths,
refer to the table on page 8.
C
12
9
C
32
11