Siemens SIPART PS2 Operating Instructions Manual page 229

Electropneumatic positioner with profibus pa
Hide thumbs Also See for SIPART PS2:
Table of Contents

Advertisement

Byte
Bit
No.
3
0
25
1
26
3
27
3
28
4
29
5
30
6
31
7
32
33 ... 48
DIAGNOSTICS_EXTENSION_2 physical block parameter
Byte
Bit
No.
0
0
49
1
50
2
51
3
52
4
53
5
54
6
55
7
56
1
0
57
1
58
2
59
3
60
4
61
5
62
6
63
7
64
SIPART PS2 with PROFIBUS PA
Operating Instructions, 05/2019, A5E00127926-AC
Diagnostics events
The device is not yet ready for
operation (not initialized)
The device is not yet ready for
operation (initialization error)
Reserved
Reserved
Device in the Manual mode (FB
in the Manual mode)
Device in the Simulation mode
(FEEDBACK is simulated)
Device in the TRACE mode
Diagnostics simulation (diag‐
nostics events are simulated)
Reserved
Diagnostics events
General control valve fault (lim‐
it 1)
General control valve fault (lim‐
it 2)
General control valve fault (lim‐
it 3)
Pneumatic leakage (limit 1)
Pneumatic leakage (limit 2)
Pneumatic leakage (limit 3)
Static friction (limit 1)
Static friction (limit 2)
Static friction (limit 3)
Lower end stop monitoring (lim‐
it 1)
Lower end stop monitoring (lim‐
it 2)
Lower end stop monitoring (lim‐
it 3)
Upper end stop monitoring (lim‐
it 1)
Upper end stop monitoring (lim‐
it 2)
Upper end stop monitoring (lim‐
it 3)
Limit 1 for path integral (100%
strokes) exceeded
Functions/operations using PROFIBUS PA
Hard-coded effect of a diagnostics event
Quality status code
Bad, configuration error
Bad, configuration error
-
-
Depends on the set status
Depends on the simulated sta‐
tus
-
Depends on the simulated di‐
agnostics event
-
Hard-coded effect of a diagnostics event
Quality status code
Good, maintenance required
Good, maintenance required
Good, maintenance required
Good, maintenance required
Good, maintenance required
Good, maintenance required
Good, maintenance required
Good, maintenance required
Good, maintenance required
Good, maintenance required
Good, maintenance required
Good, maintenance required
Good, maintenance required
Good, maintenance required
Good, maintenance required
Good, maintenance required
9.3 Cyclic data transfer
DIAGNOSTICS bit
DIA_NOT_INIT
DIA_INIT_ERR
-
-
None
None
None
Depends on the simulated di‐
agnostics event
-
DIAGNOSTICS bit
DIA_MAINTENANCE
DIA_MAINTENANCE
DIA_MAINTENANCE
DIA_MAINTENANCE
DIA_MAINTENANCE
DIA_MAINTENANCE
DIA_MAINTENANCE
DIA_MAINTENANCE
DIA_MAINTENANCE
DIA_ZERO_ERR
DIA_ZERO_ERR
DIA_ZERO_ERR
DIA_ZERO_ERR
DIA_MAINTENANCE
DIA_MAINTENANCE
DIA_MAINTENANCE
229