  Inverter Configuration – Setup Mode
Inverter Configuration – Setup Mode
You can configure the inverter using one of the following:
The internal LCD user buttons
removed.
The external LCD light button
cover is not required. This option of configuration includes a less detailed set of
menus.
Configuring the Inverter Using the Internal LCD User Buttons
After inverter installation, an installer may perform basic system configuration.
Configuration is done when the inverter is in Setup mode.
To enter Setup mode:
 1. Turn the inverter ON/OFF switch to OFF (AC remains ON).
WARNING!
If the inverter was operating properly (power was produced by the power
optimizers), the following message is displayed.
 
This message is displayed until the DC voltage is safe (50V). Do not open the
cover until the voltage is safe or until at least five minutes have passed.
 2. Press the Enter button for at least 5 seconds. The following message is displayed:
P l e a s e e n t e r
  P a s s w o r d
* * * * * * * *
 3. Use the three rightmost internal LCD user buttons to type in the following password:
12312312. The following menu is displayed:
C o u n t r y < I t a l y >
L a n g u a g e < E n g >
C o m m u n i c a t i o n
P o w e r C o n t r o l
D i s p l a y
M a i n t e n a n c e
I n f o r m a t i o n
. When using this option, the inverter cover is
. When using this option, removing the inverter
D C V O L T A G E N O T S A F E
D O N O T D I S C O N N E C T
V D C : 7 2 . 0
-Three Phase System Installation Guide MAN-01-00057-4.1