Page 1
INSPECTION CAMERA SYSTEM RICOH SC-10 SERIES Operating Instructions RICOH Industrial Solutions Inc. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 1/113...
Page 2
Be sure to read "Safety Precautions" before operation to ensure safe and correct Precautions use. RICOH Industrial Solutions Inc. assumes no liability whatsoever for any damages that occur as a result of use in a way other than described in the operating procedures of the user’s manual. ...
Page 3
(RF) CNR-102 de l’IC. Cet équipement doit être installé et utilisé en gardant une distance de 20 cm ou plus entre le radiateur et le corps humain (à l’exception des extrémités: mains, poignets, pieds et chevilles). RICOH SC-10 SERIES Operating Instructions Rev. 4.00 3/113...
Page 4
Notes to Users in the State of California (Notes to Users in USA) This product contains a Lithium Battery which contains Perchlorate Material–special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate. Hereby, RICOH Industrial Solutions Inc. declares that the radio equipment type RICOH SC-10A is in compliance with Directive 2014/53/EU. Frequency band : 2400MHz-2483.5MHz...
Page 6
Be sure to remove the power plug of the AC adapter or external power supply from the outlet. Failing to do so may cause a fire or electric shock. Also contact RICOH Industrial Solutions Inc. Do not continue using the device if it has a failure or malfunction.
Page 7
Failing to do so may cause a fire or electric shock. Also contact RICOH Industrial Solutions Inc. Do not continue using the device if it has a failure or malfunction. Keep the SD card used with this device out of the reach of infants and other small children to prevent accidental ingestion.
Page 8
Registered contents may be changed or lost due to operational errors, incorrect operation, or malfunctions. Regarding the various interfaces installed, it is not guaranteed that the all peripheral equipment connected to this product will operate correctly. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 8/113...
SC-10 Series Operating Instructions (This manual) SC-10 Series Work Instructions Editor (PC software) SC-10 Series Work Instructions Editor User's Guide SC-10 Series Socket Mode Function Operating Instructions RICOH SC-10 SERIES Operating Instructions Rev. 4.00 11/113...
Main screen: Starts/stops the workflow. When pressed for approximately 1 second: Displays the shutdown selection options (except while a workflow is being executed). When pressed for approximately 4 seconds: Forcibly turns off the power. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 12/113...
Page 13
* Focus: Broken line frame indicating that a button, menu, or other item is selected. Front of unit: ① ② ③ ② ③ ④ ① Focus adjustment ring Front cover fixing screws ② Focus fixing screws ③ Front cover ④ RICOH SC-10 SERIES Operating Instructions Rev. 4.00 13/113...
Page 14
Rear of unit: ① ③ ② ④ ⑤ External connector ① ② DC IN USB connector/SD card slot ③ LAN connector ④ HDMI connector ⑤ RICOH SC-10 SERIES Operating Instructions Rev. 4.00 14/113...
Page 15
Bottom of unit: ① ② ② ③ Tripod mount screw hole ① M4 screw holes ② ③ Tripod positioning hole RICOH SC-10 SERIES Operating Instructions Rev. 4.00 15/113...
Use an absolute search when the target is fixed. Matching mode execution screen: Displays the image set for the check points. Displays the Displays the result image set for the of matching. reference point. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 16/113...
Page 17
When the inversion of each similarity judgment logic is set (when [Inverted] is set for [Similarity] (→P. 50)), an exclamation mark (!) is displayed at the left bottom of the check point image. Exclamation mark RICOH SC-10 SERIES Operating Instructions Rev. 4.00 17/113...
Page 18
A judgment is made by comparing the number of characters and character string from the specified start point (→P. This is case sensitive. S/N (Serial number) input mode execution screen: Enter the serial number of a part and click [Set] to perform the judgment. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 18/113...
Creating a Workflow(→P. 35) STEP 3: Other Settings Configure various settings. Settings(→P. 57) Operation User Mode) / Adjustments (Administrator Mode) Operate or stop the workflow and make adjustments to the parameters. Operation(→P. 82) RICOH SC-10 SERIES Operating Instructions Rev. 4.00 19/113...
USB keyboard When connecting an external power supply Example: HDMI monitor HDMI cable USB hub External cable USB cable 24 V or 12 V power supply USB memory device USB mouse USB keyboard RICOH SC-10 SERIES Operating Instructions Rev. 4.00 20/113...
Software to instruct operations from an external device (PC, etc.) is required to use the Socket Mode function. For details, refer to the Socket Mode Function Operating Instructions of the SC-10 series. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 21/113...
Installation Check the capture field of view and installation distance in the optics graph. Optics graph: Standard model RICOH SC-10A High magnification model SC-10A (H) Installation distance (L) (mm) Installation distance (L) (mm) Field of view H Field of view H...
Page 23
Use screw(s) (sold separately) that conform to the following screw hole size. − Tripod mount (1/4") screw hole: Effective screw depth 6 mm − M4 screw hole: Effective screw depth 6 mm Bottom of unit(→P. 15) Outline Drawings(→P. 100) RICOH SC-10 SERIES Operating Instructions Rev. 4.00 23/113...
Open the USB/SD connector cover on the rear of the unit. While being careful with regard to the orientation of the SD card, insert the SD card until you hear a clicking sound. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 24/113...
Page 25
Open the LAN connector cover on the rear of the unit and connect a LAN cable. Use the included AC adapter (model including an AC adapter only). Using other than the supplied AC adapter may cause a failure. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 25/113...
Connect an external cable with a ferrite core (sold separately) attached in one place. (Seiwa E04SRS251512 or equivalent product) Start the operation of the unit after you confirm that the unit works correctly with all peripheral devices such as a monitor and power supply connected. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 26/113...
Select a work mode from the pull-down list. ③ If the corresponding location is not in the list, select the one that is the closest. Language ④ Select the display language from the pull-down list. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 27/113...
Page 28
Set the AC power frequency. ⑦ The [Initial Settings] screen can be displayed from the [Settings] menu after logging in (→P. 33). Click [OK]. The Login screen appears after restarting 29). (→P. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 28/113...
If [Do not display the login dialog] is selected in [Internal Preset], the login screen will not be displayed when starting the application (→P. 57). The user mode is enabled when the login screen is not displayed. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 29/113...
The indicator of [Preset] indicates the preset condition. − When the preset setting is not set: − When an internal preset is set: − When a Job Plan Preset is set: − When an external preset is set: RICOH SC-10 SERIES Operating Instructions Rev. 4.00 30/113...
Page 31
86). Camera image capture ⑥ Captures a camera image (→P. 37). button Camera image area Displays the camera image. ⑦ Inspection steps ⑧ Displays the inspection steps (→ P. 84). display area RICOH SC-10 SERIES Operating Instructions Rev. 4.00 31/113...
Displays the [Settings] screen 34). The [Settings] screen allows you to manage job IDs, create a Job Settings... workflow, and configure various settings. This can be selected only when logged in with [Administrator Mode]. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 32/113...
Settings... Assigns functions to the external connector pins. Displays the [Sensor Control] screen (→P. 76). Sensor Control... Set the camera sensor control. [Help] menu About... Displays the version information of the application. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 33/113...
Set the date and time (→P. 70). Setting item ② Displays the setting items of the selected setting menu item. display area ③ Save Saves the settings. ④ Cancel Cancels the settings. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 34/113...
Register a job ID by newly creating a job ID or by copying an existing job ID. STEP 3: Creating a Workflow Create workflow instructions (→P. 41). Create inspection steps (→P. 45). Save the workflow. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 35/113...
Page 36
Step list B Matching B-2 Inspection Step B-3 Check B-3 Work Flow Work instruction item C-1 Work instruction C Work instruction image C Matching C-1 (jpg file) ・ ・ ・ ・ ・ RICOH SC-10 SERIES Operating Instructions Rev. 4.00 36/113...
Display the target to be set as the master image in the camera image area. Click the camera image capture button in the main screen. Camera image capture button Camera image area You can also capture an image by double-clicking the camera image area. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 37/113...
If the check box is selected, the workflow does not stop even when it is judged to ⑦ Infinite Loop mode be fail, and the workflow is executed from the first item. [Reference ID Input ⑧ Sets the conditions for the reference ID check. Limit] RICOH SC-10 SERIES Operating Instructions Rev. 4.00 38/113...
Page 39
When [Job ID] of [Internal Preset] is enabled (→P. When [Display the Job ID input dialog when the work flow is completed] of [Internal Preset] is enabled (→P. (→P. When [Socket Mode] is enabled RICOH SC-10 SERIES Operating Instructions Rev. 4.00 39/113...
Page 40
When judging whether or not a job ID is correct when [Job ID Related] is set, use a Job ID Related list. The Job ID Related list is read at the time of login and when the [Settings] screen is closed. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 40/113...
You can also add a work instruction by right-clicking in the work instruction list and then selecting [Add to List]. Click [...] of [Instruction Step File] and set a work instruction image. The selected work instruction image appears in the work instruction image display area. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 41/113...
Page 42
A work instruction deleted from the list is also deleted from the storage device. Renaming, copying, and deleting cannot be canceled, even by clicking [Cancel] (original state is not restored). RICOH SC-10 SERIES Operating Instructions Rev. 4.00 42/113...
The [Target to Combine Instruction Steps] screen appears. Select the work instruction that is the combine target and then click [OK]. The [Confirmation] screen appears. Click [OK]. The selected work instructions are combined. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 43/113...
Page 44
After executing combining, check that the combined work instruction has been deleted from [Instruction Steps] and that the work item list of the combined work instruction has been added to the Inspection Steps of the work instruction that was the combine target. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 44/113...
Click [Add] of [Inspection Steps]. You can also add an inspection step by right-clicking in the list and then selecting [Add to List]. Select a work mode from the pull-down list of [Select Mode]. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 45/113...
Page 46
[EXTOUT] number in [External I/O Settings...]). Set the parameters of the corresponding mode. Matching mode parameters(→P. 48) Serial number (S/N) input mode parameters(→P. 53) Check mode parameters(→P. 54) RICOH SC-10 SERIES Operating Instructions Rev. 4.00 46/113...
Page 47
An inspection step deleted from the list is also deleted from the storage device. Renaming, copying, and deleting cannot be canceled, even by clicking [Cancel] (original state is not restored). RICOH SC-10 SERIES Operating Instructions Rev. 4.00 47/113...
Click the Inspection Step Reference Image. The [Inspection Step Settings] screen appears. When the mouse is moved to the master image display area, the icon appears. Click the item to set. ② ① ③ RICOH SC-10 SERIES Operating Instructions Rev. 4.00 48/113...
Page 49
The minimum size that can be specified for a check point is 30 x 30 pixels. ② Right-click in the specification area of the [Anchor point] or [Check point] and then select [Parameter Settings]. The [Parameter Settings] screen appears. Parameter Settings Copy Delete RICOH SC-10 SERIES Operating Instructions Rev. 4.00 49/113...
Page 50
If the elapsed time exceeded the time limit, the inspection step is judged to be fail and the workflow is forcibly stopped. When [One Shot] is selected in [Flow], N/A is judged to be fail. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 50/113...
Page 51
[Select Area]: Highlights the area of color similar to the set color. [Allowance]: Sets the allowance for the similarity to the set color (the similarity range becomes wider in proportion to the value). Set from 0 to 50. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 51/113...
Page 52
Judges the matching result to be fail when there is a fail judgment in the check point results. Judges the matching result to be OK when there is an OK judgment in the check point results. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 52/113...
Enter the serial number in [Part No.]. Specify [Start Point], [Num. of Char.], and [String] in [Comparison]. For details on [Start Point]/[Num. of Char.]/[String]: [Reference ID Input Limit] (→P. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 53/113...
73) of the external connector as the trigger. [Disable]: Disables the OK button. fail Configure the judgment condition (fail) settings. [Button]: Performs the judgment manually. [Disable]: Disables the fail button. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 54/113...
Select the work items to split from the selected work instruction in [Work Items] and then click [Split]. The [Confirmation] screen appears. Click [OK]. The selected work items are split and a work instruction is created. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 55/113...
Page 56
Check that the work items that were split from the instruction that was the split source have been deleted. Check that the work items you specified to be split have been registered to the work instruction that was added to [Instruction Steps]. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 56/113...
[Job ID change by external input]: Enables the external preset. Operation is the same as when [Job ID change by external input] of [External I/O Settings] (→P. 73). [External I/O Settings]: Displays the [External I/O Settings] screen (→P. 73). RICOH SC-10 SERIES Operating Instructions Rev. 4.00 57/113...
Page 58
[Job ID]: Register the preset job ID. The registered job ID is applied when starting the operation of a workflow. If the specified job ID is not registered, the [Default] job ID is applied and the preset indicator turns red. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 58/113...
Page 59
[Do not reset the number of executions when changing User ID and Job ID]: The values of [Num. of , OK], [Num. of fail], and [Total Number] are not reset even if the User ID and job ID are changed. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 59/113...
Page 60
The priority order of presets is external preset → job plan preset → internal preset. The job plan list is read at the time of login, when the Settings screen is closed, and when the job plan is completed. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 60/113...
If you change the settings, the settings cannot be restored by clicking [Cancel]. Configure the settings of the selected network connection. Wired network settings(→P. 62) Wireless network settings(→P. 63) RICOH SC-10 SERIES Operating Instructions Rev. 4.00 61/113...
Default Gateway Set the default gateway. ⑦ This can be set when [DHCP] is set to [OFF]. If you change the settings, the settings cannot be restored by clicking [Cancel]. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 62/113...
Set the subnet mask. ⑦ This can be set when [DHCP] is set to [OFF]. Default Gateway Set the default gateway. ⑧ This can be set when [DHCP] is set to [OFF]. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 63/113...
Page 64
WPA2-AES Connect Connects to the access point according to the settings specified ⑫ in [SSID], [Password], and [Security]. If you change the settings, the settings cannot be restored by clicking [Cancel]. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 64/113...
⑦ Data transmission Transmits the messages used in the Socket Mode function from ⑧ function the SC-10A to another system. Save Log Saves the messages in the log display area. ⑨ For details, refer to the Socket Mode Function Operating Instructions of the SC-10 series.
Page 66
When the Socket Mode function is enabled, the following settings for presets are disabled (masked). − [External Preset] − [Job Plan Preset] − [Internal Preset] − [Do not display the confirmation dialog] in [User Mode Settings] RICOH SC-10 SERIES Operating Instructions Rev. 4.00 66/113...
Displays the total space of the device. Free (MB) ④ Displays the free space of the device. Disconnect Select a USB device in the list and then click [Disconnect] to ⑤ safely remove the USB device. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 67/113...
Page 68
[LAN] is displayed in red when not connected. Network Folder Displays the network shared folder. ⑨ If you change the settings, the settings cannot be restored by clicking [Cancel]. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 68/113...
[One Shot]: Lights for a set time when inspection step judgment. [Keep]: Keeps the OK/fail lighting state until the next inspection step completes. Click [Save]. The settings are saved. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 69/113...
Date Time Specify a date and time and then click [Set]. ① Regional Settings Set the location where the SC-10A is installed. Specify the ② following and then click [Set]. [Area]: Select the area where the SC-10A is installed from the pull-down list (if the area is not in the list, select the one that is the closest).
Page 71
[NTP Server]: Enter the IP address of the time correction server. After you set the date and time settings, area settings, and time correction settings, the original settings cannot be restored, even by clicking [Cancel] in the settings screen. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 71/113...
The [Initial Settings] screen displayed from the [System] menu is displayed in the language selected in [Language]. ① Reset Initializes all settings items of the initial settings. The [Initial ① Settings] screen (→P. 27) is displayed after the unit restarts after a reset is executed. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 72/113...
[Monitor]: Sets the polarity for the input signal. [Job ID change by external input]: Enables the external preset. Operation is the same as when [Job ID change by external input] of [External Preset] (→P. 57). RICOH SC-10 SERIES Operating Instructions Rev. 4.00 73/113...
Page 74
“Default” and the sixth and subsequent job IDs cannot be set for the job ID of PRESET. If a job ID that is not registered to PRESET is set, [Default] is applied and the preset indicator turns red. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 74/113...
Page 75
Turns ON for a set time when each inspection step is judged to be fail. (OUT3) Set the ON timing and output time in [One Shot Time (ms)] and [ON Delay Time (ms)]. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 75/113...
Load Loads the saved white balance and exposure setting states. ⑤ Save Saves the manually set white balance and exposure setting ⑥ states. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 76/113...
Page 77
Select the job ID to which you wish to apply the sensor values from the pull-down menu and then click the [Apply] button to apply the sensor values to the specified job ID. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 77/113...
Set strings (aliases) to associate with job IDs. ⑥ area [Job ID]: Specify the job IDs to associate. This is not case sensitive. If there is an error with the input, the input area is displayed in red. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 78/113...
Page 79
The settings are saved. Describe the settings in the following order separated by commas (,) in the external file (CSV). 1. Job ID 2. Alias (string to associate) Example: ID1,index1 ID1,index2 ID2,alias1 ID2,alias2 ID2,alias3 RICOH SC-10 SERIES Operating Instructions Rev. 4.00 79/113...
If a file name has been specified in the [Settings] screen in advance, file name is displayed. ② Add a job plan. Delete ③ Delete the selected job plan. Move the selected job plan up. ④ RICOH SC-10 SERIES Operating Instructions Rev. 4.00 80/113...
Page 81
Describe the settings in the following order separated by commas (,) in the external file (CSV). 1. Job ID 2. Reference ID 3. User ID 4. Production volume Example: ID1,,,1 ID2,number1,user1,10 RICOH SC-10 SERIES Operating Instructions Rev. 4.00 81/113...
[Job ID] is registered in [Internal Preset] (→P. If [OK] is clicked without entering a job ID, the [Default] job ID is applied. You can also disable no input in [Internal Preset] (→P. 58). RICOH SC-10 SERIES Operating Instructions Rev. 4.00 82/113...
Page 83
The User ID, Job ID, and Reference ID entered when starting the work are recorded in the log (→P. 91). If you click [Cancel] on the [User ID] screen, the login screen reappears. If you click [Cancel] on [User ID] or [Reference ID] screen, the workflow stops. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 83/113...
Inspection During matching mode execution, the matching result is displayed as a ⑦ Step display thumbnail in [Anchor Point] and [Check Point], and one of the following is area displayed in [Result]. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 84/113...
Judge whether OK or fail by visually checking or click [Retry] to perform matching again. The time is not counted as processing time while the visual check dialog box is displayed. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 85/113...
(→P. − When [Job Plan Preset] is enabled (→P. − When [Job ID] of [Internal Preset] is enabled (→P. Back Goes to the previous job ID. ② Start ③ Starts the workflow. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 86/113...
Page 87
91). Any line feed included in the comment will be omitted when the comment is output to the log. The comment in the comment field is cleared after being output to the log. Shortcut Keys(→P. 93) RICOH SC-10 SERIES Operating Instructions Rev. 4.00 87/113...
Click the thumbnail in [Anchor Point] or [Check Point] in the work mode area (→P. 30) on the main screen to open the parameter settings dialog box. Parameter setting dialogs: Anchor Point RICOH SC-10 SERIES Operating Instructions Rev. 4.00 88/113...
Page 89
Click [Test] in the parameter dialog box to check the operation with the specified settings. Matching mode parameters(→P. 48) Serial number (S/N) input mode parameters(→P. 53) Check mode parameters(→P. 54) Click [OK]. The adjusted settings are reflected. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 89/113...
When the recovery or update completes, the power LED lights, a beep sounds, and the device restarts automatically. An SD card or SDHC card can be used with the device. − x: Major version − y: Minor version 1 − z: Minor version 2 RICOH SC-10 SERIES Operating Instructions Rev. 4.00 90/113...
16. Part serial number (value entered by user) When check mode: None Please note that logs are not generated if [Do not write operation logs] in [User Mode Settings] of [Preset] is enabled. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 91/113...
Image save destination folder 201901 01_JST Added serial number folder Please note that logs are not generated if [Do not write operation logs] in [User Mode Settings] of [Preset] is enabled. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 92/113...
When the button and menu cannot be selected, the shortcut key is also disabled. The shortcut keys cannot be operated when the focus is on a comment. When the Print Screen key is pressed, a screenshot of the current screen is captured. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 93/113...
Turning the ring counterclockwise moves the focus nearer (NEAR). Tighten the focus fixing screws and check that the focus adjustment ring does not turn. Attach the front cover and front cover fixing screws to the unit. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 94/113...
The distance at which the master image Use the device installed at a distance was captured and the installation that is the same as the distance at distance differ. which the master image was captured. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 95/113...
Page 96
* If the drive name is not set, the folder name may become a string unique to the device. We recommend setting the drive name before use with this device. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 96/113...
Installation distance 400 mm: 300 (H) x 150 (V) mm to installation distance 800 mm: 600 (H) x 300 (V) mm Field of view 【High magnification model RICOH SC-10A (H)】 Installation distance 400 mm: 150 (H) x 75 (V) mm to installation distance 800 mm: 300 (H) x 150 (V) mm...
Page 98
External dimensions 78 (W) x 73.5 (H) x 126.5 (D) mm (excluding connectors) Weight Approx. 400 g Mounting holes Tripod screw hole (ISO 1222 compliant), M4 screw hole x 2 RICOH SC-10 SERIES Operating Instructions Rev. 4.00 98/113...
Page 99
100 to 240 V AC / 50 to 60 Hz Ratings Output voltage +12 V ±5% Output current 2 A Max. External dimensions 50 (W) x 34 (H) x 88.5 (D) mm (excluding cable) Weight Approx. 170 g RICOH SC-10 SERIES Operating Instructions Rev. 4.00 99/113...
Outline Drawings Front of unit: Top of unit: Side of unit: Bottom of unit: 2M4, effective screw depth 6 1/4-20 UNC, effective screw depth 6 4.6 hole, depth RICOH SC-10 SERIES Operating Instructions Rev. 4.00 100/113...
Hot plugging is not supported for SD cards and HDMI. If you wish to use an SD card or HDMI cable, turn off the power of the device before connecting the SD card or HDMI cable. RICOH SC-10 SERIES Operating Instructions Rev. 4.00...
External I/O control: Output circuit diagram The driving current of the output transistor is 4 mA (typ.). The connection of an external device which supplies large current may cause incorrect operation. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 102/113...
The actual high or low level differs according to the specified polarity setting in [External I/O Settings]. For details on the signal names, refer to the descriptions for [External I/O Settings] (→P. 73). When the workflow is judged to be OK RICOH SC-10 SERIES Operating Instructions Rev. 4.00 103/113...
Page 104
When the workflow is judged to be fail RICOH SC-10 SERIES Operating Instructions Rev. 4.00 104/113...
Page 105
When the workflow is stopped RICOH SC-10 SERIES Operating Instructions Rev. 4.00 105/113...
Page 106
The base for the ON delay time (delay in the figure) is when the OK/fail judgment of the inspection step is determined and BUSY changed from ON to OFF. Please note that you cannot proceed to the next state until all outputs set for One Shot output complete. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 106/113...
The flow is the same regardless of the [Check Method] setting ([Matching], [Color Recognition], or [Textured]) (→P. 50). If check points are not set, the searches in the dotted line area are not performed. RICOH SC-10 SERIES Operating Instructions Rev. 4.00 107/113...
In the event that this product fails, it will be repaired free of charge within one year of the date of purchase, so please contact RICOH Industrial Solutions Inc. You may need to bear some of the costs of shipment depending on the shipping method.
Page 110
Check mode parameters − Addition: [External Input] function − Addition: [External Output] function 10.Settings Addition: [Preset] function Addition: [External I/O Settings] function Addition: [Sensor Control] function 11.Operation Starting of Operation RICOH SC-10 SERIES Operating Instructions Rev. 4.00 110/113...
Page 111
Addition: The function that number of executions is not reset − Addition: [Job Plan Preset] function − Addition: Setting the [Internal Preset] − Addition: User Mode Settings Sound / LED Settings RICOH SC-10 SERIES Operating Instructions Rev. 4.00 111/113...
Page 112
Replacement and addition: Images and explanations due to UI changes 9.Creating a Workflow Registering/Managing Job IDs − Addition: When Socket Mode is enabled to ⑨ Production volume management − Addition: ⑫ Sensor settings Combining Work Instructions RICOH SC-10 SERIES Operating Instructions Rev. 4.00 112/113...