Opening Conduit Drill Guides - SolarEdge EV Series Installation Manual

Charging single phase inverter with setapp configuration
Table of Contents

Advertisement

DIP Switches
Set the circuit breaker rating DIP switches (see Figure 12 ).
Figure 12: Safety Switch with EV Charger internal interfaces
To set the circuit breaker ratings:
Use the circuit breaker rating DIP switches to set circuit breaker ratings.
 
Circuit Breaker Rating
 
20 A
30 A
40 A
50 A
Buzzer
The EV charger includes a buzzer with the following indications:
Event
Connected to EV
Charging starts
Error

Opening Conduit Drill Guides

This step may be performed before or after mounting the inverter.
EV Charging Single Phase Inverter Guide MAN-01-00588-1.1
DIP Switch Settings
1 (left)
2 (right)
OFF
OFF
ON
OFF
OFF
ON
ON
ON
2 short beeps + 1 long beep
Chapter 3: Installing the Inverter
Maximum Allowed
AC Current from Grid
16 A
24 A
32A
40 A
Buzzer Indication
1 short beep
5 beeps
    33