90
  Technical Specifications - Three Phase Inverters (Europe & APAC)
Residual current
detector / Residual
Current step detector
Grid supported –
three phase
Inrush current AC
(Peak/ Duration)
Maximum output
fault current
Power factor range
Total harmonic
distortion
Protective class
Utility monitoring,
islanding protection,
configurable Power
Factor, country
configurable
thresholds
Overvoltage category
Input
Maximum DC power
(Module STC)
Transformer-less,
ungrounded
Maximum input
voltage
Nominal DC input
voltage
Maximum input
current
Maximum back-feed
current
Reverse-polarity
protection
(1) For SE27.6K - when set to Germany Power Factor is limited to 0.9.
SE15K
SE16K
SE17K
3 / N / PE (WYE with Neutral)
3/ 20
40
1 (adjustable from -0.9 to
+0.9)
20250
21600
22950
22
23
-Three Phase System Installation Guide MAN-01-00505-1.2
SE25K
SE27.6K
300 / 30
3.1/ 20
  63
1 (adjustable from -0.8 to
+0.8)
< 3%
Class I
Yes
III
33750
37250
Yes
900
750
23
37
40
0
Yes
SE33.3K
Unit
mA
V
Aac
4.2/ 20
(rms) /
ms
A
(1)
45000
W
1000
Vdc
840
Vdc
40
Adc
Adc