  Technical Specifications - Three Phase Inverters (Europe & APAC)
Additional Features
Supported
communication
interfaces
Inverter
commissioning
RS485 Surge
Protection
Smart Energy
Management
Arc Fault Protection
Standard Compliance
Safety
Grid connection
(1)
standards
Emissions
WEEE, RoHS
Installation Specifications
AC output / Gland
Diameter / Wire Cross
Section
DC input
Dimensions (WxLxH)
Weight
Operating
(3)
temperature range
Operating humidity –
non condensing
Cooling
(1) For all standards refer to the Certifications category in
http://www.solaredge.com/groups/support/downloads
(2) You can connect strings in parallel to a single input as long as the cumulative current does not exceed 45A.
(3) For inverter power de-rating refer to the application note at the following link:
http://www.solaredge.com/files/pdfs/se-temperature-derating-note.pdf
(4)
Provided with the inverter in India only. For other countries an SPD plug-in can be purchased. Refer to
https://www.solaredge.com/sites/default/files/se_spd_plug_in_for_rs485_3ph_setapp_ds.pdf
SE4K
SE5K
SE7K
2 x RS485, Ethernet, Built-in GSM (Optional)
With the SetApp mobile application using built-in Wi-Fi
station for local connection
Integrated, user configurable (according to UL1699B)
IEC-62103 (EN50178), IEC-62109
VDE 0126-1-1, VDE-AR-N-4105, AS-4777, G83 / G59
IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-
FCC part15 class B
15-21 mm / Solid wire 2.5-16 mm
Fan (user replaceable)
-Three Phase System Installation Guide MAN-01-00505-1.2
SE8K
SE9K
Optional
(4)
Export Limitation
12,
Yes
2
, Stranded wire 2.5 - 10
2
mm
(2)
2 MC4 pairs
540 x 315 x 260
33.2
-40 - +60
< 95
.
SE10K
SE12.5K
Unit
mm
kg
°C
%