SolarEdge SE5K Installation Manual page 54

Three phase system with setapp configuration for europe and apac
Hide thumbs Also See for SE5K:
Table of Contents

Advertisement

To connect the Ethernet cable:
 1. Remove the inverter cover .
 2. Open the communication gland #1.
CAUTION!
The gland includes a rubber waterproof fitting, which should be used to
ensure proper sealing.
 3. Remove the plastic seal from one of the large opening .
 4. Remove the rubber fitting from the gland and insert the CAT5/6 cable through the
gland and through the gland opening in the inverter .
 5. Push the cable into the cut opening of the rubber fitting.
CAT5/6 standard cables have eight wires (four twisted pairs), as shown in the diagram
below. Wire colors may differ from one cable to another. You can use either wiring
standard, as long as both sides of the cable have the same pin-out and color-coding.
Three Phase System Installation Guide MAN-01-00505-1.2
Figure 19: Example of Ethernet connection
Figure 20: Rubber fitting
Chapter 6: Setting Up Communication