Step 3: Verifying Proper Activation And Commissioning; Viewing System Status - SolarEdge SE5K Installation Manual

Three phase system with setapp configuration for europe and apac
Hide thumbs Also See for SE5K:
Table of Contents

Advertisement

40
  Step 3: Verifying Proper Activation and Commissioning
Hardware IDs: Displays the following HW serial numbers (if exist, and
connected to the inverter):
This inverter: the inverter's ID
Meter # : Energy meter ID (up to 3 meters can be connected)
ZB: ZigBee Plug-in MAC address
WiFi: Wi-Fi MAC address
Error Log: Displays the last five errors, and enables resetting (clearing) the log.
Warning Log: Displays the last five warnings, and enables resetting (clearing)
the log.
Step 3: Verifying Proper Activation and
Commissioning
 1. Select Information and verify that the correct firmware versions are installed on each
inverter.
 2. Select Status and verify that inverter is operating and producing power (see also
Viewing System Status on page 40).
 3. Verify that additional configurations were properly set by viewing the relevant
Status screens.
 4. Verify that the green inverter LED is steadily lit.
Your SolarEdge power harvesting system is now operational.

Viewing System Status

During normal operation, the Status screen displays all the inverter settings and
operation status. Scroll up or down to display various status parameters as described in
the following sections.
The LED indication provides more information about system performance; Refer to LEDs
on page 22.
To access the Status screen:
From the Commissioning menu select Status. The main inverter Status screen is
displayed (see below).
A red or orange icon (for example:
indicating an error. The color indicates error severity (red is top severity). The error
description or information appears on the screen. Tap the error line for more
information and troubleshooting instructions, and refer to Errors and Troubleshooting
on page 62.
) may appear at the top left corner of a status cell,
-Three Phase System Installation Guide MAN-01-00505-1.2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents