Summary of Contents for Immergas VICTRIX ZEUS SUPERIOR 26 2 ERP
Page 1
VICTRIX ZEUS Instruction and recommendation booklet SUPERIOR 26 2 - 32 2 ERP...
Page 3
Read the following pages carefully: you will be able to draw useful suggestions regarding the correct use of the appliance, the respect of which, will confirm your satisfaction for the Immergas product.
The place of installation of the appliance and Failure to comply with the above implies personal relative Immergas accessories must have suitable responsibility and invalidates the warranty. features (technical and structural) such to allow •...
2 (EN 1717:2002). The materials used for the central heating circuit of Immergas boilers withstand ethylene and propylene glycol based antifreeze liquids (if the mixtures are prepared perfectly). For life and possible disposal, follow the sup- plier's instructions.
The gas supply pipe must be suitably ply respecting L-N polarity and earth connection; dimensioned according to current regulations Attention: Immergas declines all liability in the , this network must also have a multi-pole cir- in order to guarantee correct gas flow rate to the event of damage caused by the inclusion of auto- cuit breaker with class III over-voltage category.
All Immergas chrono-thermostats are connected precision and therefore with evident saving probe. The probe can be connected directly to with 2 wires only. Carefully read the user and in running costs.
• Coupling extension pipes and concentric Attention: the boiler must be installed ex- elbows. To install push-fitting extensions with clusively with an original Immergas “Green other elements of the flue, proceed as follows: Range” inspectionable air intake device and Install the concentric pipe or elbow with the...
Page 10
Equivalent Resistance Equivalent Equivalent length Equivalent length length in m TYPE OF DUCT Factor length in metres in metres of pipe in m of concentric of concentric pipe of pipe Ø 80 Ø 60 pipe Ø 80/125 Ø 60/100 Intake m 7.3 Concentric pipe Ø...
(B ) or ducted directly outside via a vertical terminal for direct exhaust (B or via an Immergas ducting system (B The technical regulations in force must be respected. • Coverage kit assembly (Fig. 1-11). Remove the cap and gasket from the intake hole.
Make sure that the external silicone wall concentric bend leaving the boiler. If addi- Immergas also provides a Ø 60/100 simplified sealing plate is properly inserted in the wall. tional components are assembled, the length terminal, which in combination with its exten- N.B.: for proper system operation the terminal...
1.13 CONCENTRIC VERTICAL KIT male side (5) (smooth) into the flange (2) up to Position the fixed half-shell (5) on the aluminium INSTALLATION. the end stop; making sure that the wall sealing tile and insert the intake-exhaust pipe (7). Fit the Type C configuration, sealed chamber and plate has been fitted (3), this will ensure sealing 80/125 Ø...
1.14 SEPARATOR KIT INSTALLATION. side (smooth) to the female side of the bend Type C configuration, sealed chamber and (5) up to the end stop; making sure that the fan assisted. internal wall sealing plate has been fitted, this will ensure sealing and joining of the elements Separator kit Ø...
N.B.: to encourage the removal of possible - The maximum vertical extension using a Ø 60 This kit allows an Immergas boiler to be installed condensate forming in the exhaust pipe, tilt ducting system is 13 m, the maximum exten- in "C...
1.19 FLUES, CHIMNEYS, CHIMNEY POTS 1.22 GAS SYSTEM START-UP. AND TERMINALS. To start up the system, refer to the technical The flues, chimneys and chimney pots for the standard in force. evacuation of combustion products must be in In particular, for new gas systems: compliance with applicable standards.
Furthermore, within the parameter it is pos- 2 ErP). sible to adjust the operation range of the circulator setting limit speed (adjustable from 83 % for model Victrix Zeus Superior 26 2 ErP Head available to the system. 1-28 Victrix Zeus Superior 26 2 ErP...
The boiler is prepared for of the pump kit. Immergas supplies a series of empty just the boiler without having to empty application of the polyphosphate dispenser kit.
USE AND MAINTENANCE ensure that a qualified technician checks the ef- not be disposed of like normal household waste ficiency of the ducting or other devices. nor abandoned in the environment, but must be INSTRUCTIONS Never clean the appliance or connected parts removed by a professionally qualified firm.
DESCRIPTION OF FUNCTIONING means of the indicator (6) with a brief descrip- STATES tion. Refer to the instruction book for a complete Below find a list of boiler functioning states that explanation. appear on the multifunction display (24) by Display (6) Description of functioning states Summer functioning mode without request in progress.
2.5 USING THE BOILER. • Functioning with external probe (Fig. 2-6) Adjustment of the system flow temperature optional. In the case of a system with optional Before ignition make sure the central heating sys- tem is filled with water and that the manometer external probe, the boiler flow temperature (23) indicates a pressure of 1 - 1.2 bar;...
2.6 TROUBLESHOOTING. to the following example (e.g. CAR = Exx, Super The Victrix Zeus Superior ErP boiler signals CAR = ERR>xx). any anomalies by the flashing symbol (5) along with the “ERRxx” indication on the indicator (6) where “xx” corresponds to the error code described in the following table.
Page 24
Error Anomaly signalled Cause Boiler status / Solution Code If the board detects an anomaly on the flue gas probe the boiler will not Flue probe anomaly start Power cycle the boiler. If the Remote Con- trol is still not detected on re-starting the boiler will switch to local operating mode, Loss of remote This occurs in the event of connection to a non compatible remote control...
2.7 PARAMETERS AND INFORMATION - “M3” customisations By turning the central heating temperature se- MENU. lector switch (3) scroll through the menu items. - “M5” configurations: menu reserved to the By pressing the button "D" it is possible to access By pressing button “D”...
1 and 1.2 bar. If the pressure falls below 1 bar (with the circuit of the Immergas Anti-freeze Kit in the boiler. In cold) restore normal pressure via the valve located the case of prolonged inactivity (second case), we also recommend that: at the bottom of the boiler (Fig.
BOILER START-UP (INI- and central heating modes; - check ventilation and/or aeration of the instal- lation room where provided. TIAL CHECK) - check the CO in the fumes at maximum and minimum flow rate; If even only a single safety check offers a negative To commission the boiler: result, do not commission the system.
(about 30 sec.). pressure points (18 and 20 Fig. 1-29). Attention: the CO verification operations must Victrix Zeus Superior 26 2 ErP Access the configurations menu under the “SER- be carried out with the casing mounted, while the at nominal at minimum VICE"...
3.8 PROGRAMMING THE P.C.B. By pressing the button "D" it is possible to access Listed below are the items in the“M5” menu The boiler is prepared for possible programming the main menu, divided into three main parts: with default parameters and possible options of several operation parameters.
Page 31
M5 menu (password must be entered) Value Default 1st Level 2nd Level Options Description value by the tech- nician With the external probe present it defines at which minimum external temperature the boiler must operate at the maximum flow temperature (see P66/C graph Fig.
M5 menu (password must be entered) Value Default 1st Level 2nd Level Options Description set by the value technician RELE3-0 Relay 3 not used Check the storage tank recirculation pump RELE3-1 (not used on this model) The relay signals the intervention of boiler block ( Can be coupled to an RELE3-2 external signalling device, not supplied) The relay signals that the boiler is on and in the heating stage...
3.16 APPLIANCE CHECK AND - Check the operation of the appliance control MAINTENANCE. and adjustment devices and in particular: The following checks and maintenance should - intervention of the main electrical switch on be performed at least once a year. the boiler;...
3.17 CASING REMOVAL. - Unscrew the 2 (6) fastening screws of the casing To facilitate boiler maintenance the casing can front (7) and release it by pushing it up. be completely removed by following these simple - Loosen the screws (8) in the lower part of the instructions (Fig.
3.21 KEY FOR DATA NAMEPLATE. Cod. Md Sr N° Cod. PIN Type n min. max. n min. n max. Class CONDENSING N.B.: the technical data is provided on the data plate on the boiler Model Cod. Md Model code Sr N° Serial Number Check Cod.
Contact information IMMERGAS S.p.A. VIA CISA LIGURE, 95 - 42041 BRESCELLO (RE) ITALY (*) High temperature mode means 60°C on return and 80°C on flow. (**) Low temperature mode for condensation Boilers means 30°C , for low temperature boilers 37°C and for other appliances 50°C of return tempera- ture.
3.23 PRODUCT DATA SHEET (IN COMPLIANCE WITH REGULATION 811/2013). Victrix Zeus Superior 26 2 ErP Victrix Zeus Superior 32 2 ErP VICTRIX ZEUS SUPERIOR 26 2 ErP VICTRIX ZEUS SUPERIOR 32 2 ErP Parameter value Parameter value Yearly energy consumption for the heating Yearly energy consumption for the heating 40.3 GJ...
3.24 PARAMETERS FOR FILLING IN THE to make up the assembly (e.g. solar devices, in- ASSEMBLY SHEET. tegration heat pumps, temperature controllers). In case you should wish to install an assembly, Use sheet fig. 3-8 for “assemblies” related to starting from the Victrix Zeus Superior ErP the heating function (e.g.: boiler + temperature boiler (26 2 or 32 2), use the assembly charts in controller).
Page 42
Parameters for filling in assembly chart. Parameter Victrix Zeus superior 26 2 ErP Victrix Zeus superior 32 2 ErP ‘I’ ‘II’ ‘III’ 1,27 0.84 ‘IV’ 0,50 0.33 * to be established by means of table 5 of Regulation 811/2013 in case of “assembly” including a heat pump to integrate the boiler.
Page 43
Facsimile for filling in domestic hot water production system assembly chart. Water heating energy efficiency of combination heater ‘I’ Declared load profile: Solar contribution From fiche of solar device Auxiliary electricity ( 1,1 ‘I’ 10 % ) ‘II’ ‘III’ ‘I’ Water heating energy efficiency of package under average climate Water heating energy efficiency class of package under average climate <...
Page 44
Parameters for filling in DHW package assembly chart. Parameter Victrix Zeus superior 26 2 ErP Victrix Zeus superior 32 2 ErP ‘I’ ‘II’ ‘III’ * to be determined according to Regulation 811/2013 and transient calculation methods as per Notice of the European Community no. 207/2014.
Page 48