Display
Display
Select Display to set the following:
T e m p e r a t u r e
L C D
O n
Temperature: Select Celsius or Fahrenheit units.
l
LCD On Time <30>: The number of seconds that the LCD backlight is ON after pressing the LCD light
l
button. Set a value within the range of 10-120 seconds.
Maintenance
Select Maintenance to set the following options:
D a t e
a n d
R e s e t
C o u n t e r s
F a c t o r y
F W
U p g r a d e
A F C I
< D i s >
D i a g n o s t i c s
S t a n d b y
G r i d
P r o t e c t i o n
B o a r d
R e p l a c e m e n t
Date and Time: Set the internal real-time clock. If connected to the SolarEdge monitoring platform,
l
the date and time are set automatically and only time zone should be set.
Reset Counters: Resets the accumulated energy counters that are sent to the SolarEdge monitoring
l
platform
Factory Reset: Performs a general reset to the d efault device settings.
l
FW Upgrade: Perform a software upgrade b
l
an_inverter_using_micro_sd_card.pdf.
Diagnostics: Displays the Isolation Status and optimizers status screens. Refer to
l
http://www.solaredge.us/files/pdfs/application_note_isolation_fault_
troubleshooting.pdf.
AFCI: Enables or disables arc-fault self-test. Refer to
l
http://www.solaredge.com/sites/default/files/arc_fault_detection_application_
note_na.pdf .
Standby Mode: Enables/disables Standby Mode - for remote commissioning.
l
Grid Protection: Available in specific countries. Enables viewing and setting grid protection values.
l
Optimizer Conf.: Opens t he Rapid Shutdown menu, to enable/disable PVRSS.
l
44
Single Phase Inverter with HD-Wave Technology Installation MAN-01-00306-1.1
< C >
T i m e
< 3 0 >
T i m e
R e s e t
M o d e
y using an SD card. Refer to upgrading_