PCU Section
PCU
1. Toner bottle with the holder [A]
2. Open the right door.
3. Press the latch [B] and pull out the PCU [C].
• Do not touch the OPC drum surface with bare hands.
4. Load new developer (
5. Do SP 2214 to reinitialize the TD sensor when you reassemble.
p.105 "Developer").
PCU Section
4
101