VICTRIX
Instruction and
IE
warning book
SUPERIOR
32 X 2 ErP

Advertisement

Table of Contents
loading

Summary of Contents for Immergas Victrix Superior 32 X 2 ErP

  • Page 1 VICTRIX Instruction and warning book SUPERIOR 32 X 2 ErP...
  • Page 3 Read the following pages carefully: you will be able to draw useful suggestions regarding the correct use of the appliance, the respect of which, will confirm your satisfaction for the Immergas product.
  • Page 4: Table Of Contents

    1.8 External temperature probe (Optional)... 8 2.9 Draining the system.......... 25 3.8 Programming the P.C.B........32 1.9 Immergas flue systems........9 2.10 Anti-freeze protection........25 3.9 "Chimney sweep function" (F2)...... 34 1.10 Tables of Resistance Factors and 2.11 Case cleaning.
  • Page 5: Boiler Installation

    1.1 INSTALLATION Technical Assistance centre, which has RECOMMENDATIONS. specifically trained staff and original spare The Victrix Superior 32 X 2 ErP boiler has parts). Do not attempt to modify or repair the been designed for wall mounted installation appliance alone.
  • Page 6: Main Dimensions

    2 (EN 1717:2002). The materials used for the central heating circuit of Immergas boilers resist ethylene and propylene glycol based antifreeze liquids (if the mixtures are prepared perfectly). For life and possible disposal, follow the sup- plier’s instructions.
  • Page 7: Gas Connection

    1.5 HYDRAULIC CONNECTION. 1.6 ELECTRICAL CONNECTION. CATEGORY II Attention: In order not to void the warranty The “Victrix Superior 32 X 2 ErP” boiler has an 2H3P Our boilers are designed to operate with methane before making the boiler connections, carefully IPX5D protection rating for the entire appliance.
  • Page 8: Remote Controls And Room Chrono-Thermostats (Optional)

    The are available as optional kits. All Immergas chrono-thermostats are connected running costs. The CAR is supplied directly probe can be connected directly to the boiler by the boiler by the same 2 wires used for the electrical system and allows the max.
  • Page 9: Immergas Flue Systems

    (smooth) on the female section Attention: the boiler must be installed (with lip seal) to the end stop on the previously exclusively with an original Immergas “Green installed element in order to ensure sealing Range” inspectionable air intake device and efficiency of the coupling.
  • Page 10 Equivalent Equivalent Resistance Equivalent Equivalent length in m of length in m of TYPE OF DUCT Factor length in metres length in metres concentric pipe concentric pipe of pipe Ø80 of pipe Ø60 Ø60/100 Ø80/125 Intake m 7.3 Concentric pipe Ø60/100 Intake and Exhaust m 1.9 m 3.0...
  • Page 11: Outdoor Installation In Partially Protected Area

    (B It is recommended but not compulsory. or via an Immergas ducting system (B The technical regulations in force must be respected. • Kit assembly (Fig. 1-10): Remove the two plugs and the gaskets present from the two lateral holes with respect to the central one.
  • Page 12: Horizontal Concentric Kit Installation

    1.12 HORIZONTAL CONCENTRIC KIT Horizontal intake - exhaust kit Ø60/100. Kit Horizontal intake - exhaust kit Ø80/125. Kit INSTALLATION. assembly (Fig. 1-14): for the installation of kit assembly (Fig. 1-12): install the bend with flange Type C configuration, sealed chamber and (2) on the central hole of the boiler, positioning Ø80/125 the flanged adapter kit must be used to fan assisted.
  • Page 13: Vertical Concentric Kit Installation

    1.13 VERTICAL CONCENTRIC KIT tile with the aluminium sheet (4), shaping it to be able to install the flue system Ø80/125. Install INSTALLATION. ensure that rainwater runs off. Position the fixed the flanged adapter (2) on the central hole of the Type C configuration, sealed chamber and half-shell (6) and insert the intake-exhaust pipe boiler, positioning the gasket (1) with the circular...
  • Page 14: Separator Kit Installation

    1.14 SEPARATOR KIT INSTALLATION. making sure that the internal wall sealing plate Type C configuration, sealed chamber and has been fitted, this will ensure sealing and fan assisted. joining of the elements making up the kit. • Installation clearance (Fig. 1-21). The minimum Separator kit Ø80/80.
  • Page 15: Adapter Kit Installation C9

    The current kit allows for the installation of one condensate forming in the exhaust pipe, tilt ducting system of Ø60 is 13 m, the maximum Immergas boiler in configuration "C ", carrying the pipes towards the boiler with a min. slope extension includes 1 bend Ø60/10 at 90°, 1 m...
  • Page 16: Ducting Of Flues Or Technical Slots

    Ø80 flexible “Green Range” ducting systems must length is obtained considering the complete relevant terminal. The multiple flues and the only be used for domestic use and with Immergas Ø80 exhaust terminal, 1m of Ø80 pipe in combined flues must also only be connected to condensing boilers.
  • Page 17: Flues, Chimneys, Chimney Caps And Terminals

    Vent the initial inspection of the boiler, which is required to circulation pump by loosening the front cap and activate the Immergas warranty. The test certificate keeping the motor running. Re-tighten the cap and warranty is issued to the user.
  • Page 18: Circulation Pump

    1.24 CIRCULATION PUMP. By-pass Regulation (part. 25 Fig. 1-28). The - ∆T Constant (∆T = 5 ÷ 25 K): at variable boiler is supplied with by-pass closed by 1.5 turns The boilers are supplied with a built-in circulation pump speed to keep the ∆T constant between pump with variable speed.
  • Page 19: Kits Available On Request

    • Cover kit (on request). If installed outdoors in a • System cut-off valve kits with or without water flow rate high for each zone, Immergas partially protected place with direct air intake, inspectionable filter (on request). The boiler is supplies zone system kits on request.
  • Page 20: Instructions For Use And Maintenance

    Annual maintenance is not be disposed of like normal household waste with easily flammable substances. essential to validate the Immergas warranty. We nor abandoned in the environment, but must Never leave containers or flammable substances recommend stipulating a yearly cleaning and be removed by a professionally authorised in the same environment as the appliance.
  • Page 21: Description Of Functioning States

    2.4 DESCRIPTION OF FUNCTIONING STATES. Below find a list of boiler functioning states that appear on the multifunction display (24) by means of the indicator (6) with a brief description. Refer to the instruction book for a complete explanation. Display (6) Description of functioning states Summer functioning mode without request in progress.
  • Page 22: Using The Boiler

    2.5 USING THE BOILER. selector switch (3) in a clockwise direction the hour, giving the functioning priority to room Attention: the Victrix Superior 32 X 2 ErP boiler temperature increases and in an anti-clockwise central heating has been designed to operate as an appliance for direction it decreases.
  • Page 23: Troubleshooting

    2.6 TROUBLESHOOTING. The Victrix Superior 32 X 2 ErP boiler signals any anomalies by the flashing symbol (5) along with the “ERRxx” indication on the indicator (6) where “xx” corresponds to the error code described in the following table. On the possible...
  • Page 24 Error Anomaly signalled Cause Boiler status / Solution Code This occurs if there is overheating in the boiler due to insufficient water circulating in the primary circuit; the causes can be: Insufficient circula- Press the Reset button (1). - low system circulation; check that no shut-off devices are closed on the tion central heating circuit and that the system is free of air (deaerated);...
  • Page 25: Boiler Shutdown

    2.10 ANTI-FREEZE PROTECTION. Switch the boiler off by pressing the “ ” button, The “Victrix Superior 32 X 2 ErP” series boiler disconnect the onmipolar switch outside of the has an anti-freeze function that switches on boiler and close the gas cock upstream from the automatically when the temperature falls appliance.
  • Page 26: Parameters And Information Menu

    2.13 PARAMETERS AND INFORMATION - “M9” setting. MENU. By turning the heating temperature selector By pressing the button "D" it is possible to access switch (3) scroll through the menu items. By a menu divided into three main parts: pressing button “D” access the various levels - Information “M1”...
  • Page 27 Zones Menu. The menu zone is only activated if the board detects a connection to a board on an additional zone (optional). This menu contains the temperature functioning settings in the additional zones. Level Button Level Button Description D  Displays the current temperature of the low temperature zone number 2.
  • Page 28: Boiler Commissioning (Initial Check)

    BOILER COMMISSIONING - check the ∆p gas values in DHW mode (when - check the production of DHW (when the boiler the boiler is connected to an external storage tank is connected to an external storage tank unit); (INITIAL CHECK) unit) and in central heating mode;...
  • Page 29: Wiring Diagram

    3.2 WIRING DIAGRAM. R8 - Storage tank resistance S5 - System pressure switch S20 - Room thermostat (optional) S34 - System supervisor connection selector Super CAR - SUPER Comando Amico Remoto remote control (optional) T1 - Low voltage feeder X40 - Environment thermostat jumper Y1 - Gas valve 1 - Status signal 2 - IMG BUS connection...
  • Page 30: Converting The Boiler To Other Types Of Gas

    Key: Gas Valve 8205 Gas Valve 848 1 - Gas valve inlet pressure point 2 - Gas valve outlet pressure point 3 - Off/Set adjustment screw 12 - Outlet gas flow rate adjuster P.C.B. Key: 4 - 3,15 AF fuse 5 - S34 selector: On = external probe;...
  • Page 31: Adjustment Of The Air-Gas Ratio

    3.6 ADJUSTMENT OF THE AIR-GAS RATIO. Attention: the verification operations of the CO must be carried out with the casing mounted, while the gas valve calibration operations must be carried out with the casing open and removing the voltage from the boiler. Calibration of the minimum CO (minimum heating power).
  • Page 32: Programming The P.c.b

    - Information “M1” (See “User” Chapter). Below find the items in the“M5” menu with default parameters and possible options The Victrix Superior 32 X 2 ErP boiler is prepared - Customisations “M3” (See “User” Chapter). for possible programming of several operation indicated.
  • Page 33 M5 menu (password must be entered) Value Default Level Level Options Description value by the technician In winter mode the pump is always powered and so functions P67.1 continuously. In winter mode the pump is managed by the room thermostat or by the P67.2 P67.2 remote control.
  • Page 34: Chimney Sweep Function" (F2)

    M5 menu (password must be entered) Value Default Level Level Options Description value by the technician RELE3-0 Relay 3 not used. Check the storage tank recirculation pump RELE3-1 (when the boiler is connected to an external storage tank) The relay signals the intervention of boiler block RELE3-2 ( Can be coupled to an external signalling device, not supplied).
  • Page 35 - The intervention of the DHW adjustment thermostat (when the boiler is connected to an external storage tank unit). - Check sealing efficiency of the gas circuit and the internal system. - Check the intervention of the device against no gas ionisation flame control. The relative intervention time must be less than 10 seconds.
  • Page 36: Variable Heat Power

    3.18 VARIABLE HEAT POWER. sealed chamber (see pressure test 32 and 33 Fig. measuring 0.5 m in length. Gas flow rates refer N.B.: the pressures indicated in the table 1-20). The adjustments must be performed using to heating values below a temperature of 15°C represent the differences of pressures at the a digital differential manometer with a scale in and at a pressure of 1013 mbar.
  • Page 37: Technical Data

    Automatic (**) Min. pressure (dynamic) domestic hot water circuit (**) Domestic hot water circuit max. working pressure (**) (*) Specific capacity “D” UB Immergas Inox 80-2 according to EN 625 l/min 21,8 (**) (*) Specific capacity “D” UB Immergas Inox 120-2 according to EN 625...
  • Page 38: Data Plate Key

    3.21 DATA PLATE KEY. Cod. Md Sr N° Cod. PIN Type n min. max. n min. n max. Class CONDENSING Note: the technical data are shown on the boiler data plate Model Cod. Md Model code Sr N° Serial Number Check Cod.
  • Page 39: Technical Parameters For Mixed Boilers (In Compliance With Regulation 813/2013)

    Contact details IMMERGAS S.p.A. VIA CISA LIGURE, 95 - 42041 BRESCELLO (RE) ITALY (*) High-temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet. (**) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other heaters 50 °C return temperature.
  • Page 40: Parameters For Filling In The Assembly Sheet

    In case you should wish to install an assembly, to make up the assembly (e.g. solar devices, in- starting from the Victrix Superior 32 X 2 ErP tegration heat pumps, temperature controllers). boiler, use the assembly charts in fig. 3-8 and Use sheet fig.
  • Page 41 Parameters for filling in the assembly chart. Parameter Victrix Superior 32 X 2 ErP ‘I’ ‘II’ ‘III’ 0,84 ‘IV’ 0,33 * to be established by means of table 5 of Regulation 811/2013 in case of “assembly” including a heat pump to integrate the boiler. In this case the boiler must be considered as the main appliance of the assembly.
  • Page 42 Example to fill in the domestic hot water production system assembly chart. Water heating energy efficiency of combination heater ‘I’ Declared load profile: Solar contribution From fiche of solar deviee Auxiliary electricity ( 1,1 x ‘I’ 10 % ) ‘II’ ‘III’...
  • Page 43 Parameters for filling in DHW package assembly chart. Parameter Victrix Superior 32 X 2 ErP ‘I’ ‘II’ ‘III’ * to be determined according to Regulation 811/2014 and transient calculation methods as per Notice of the European Community no. 207/2014. 3-10 Domestic hot water production system assembly chart.
  • Page 44 Follow us Immergas Italia immergas.com Immergas S.p.A. 42041 Brescello (RE) - Italy Tel. 0522.689011 Fax 0522.680617 Certified company ISO 9001 ИЗКЛЮЧИТЕЛЕН ПРЕДСТАВИТЕЛ И СЕРВИЗ АМАКС ГАЗ ООД 1261 Мрамор, София ул В. Левски 148 Tel. 0700 112 66 Fax 02 902 46 70...