Pre-mixed wall-mounted condensing boiler for central heating and
the production of DHW, with sealed chamber and fan-assisted with
nominal heat output of 23.6 kW in CH mode (26 kW in DHW
mode) with high efficiency and fan-assisted circulation. By varying
the type of installation the classification of the boiler also varies.
OuTDOOR INsTaLLaTION (in partially protected place):
appliance with direct air intake - if installed using a flue terminal
and the (optional) mandatory top cover kit, also eliminating a sealed
chamber intake cap.
appliance type C
/ C
/ C
- if installed using the vertical or horizontal
13
33
83
concentric kits (cover kit recommended but not mandatory) or the Ø
80/80 separator kit without using the top cover kit.
INDOOR INsTaLLaTION:
appliance type C
/ C
/ C
/ C
13
33
43
or horizontal concentric kits or the Ø 80/80 separator kit.
appliance type B
- if installed using a flue kit and the (optional) man-
23
datory top cover kit, also eliminating a sealed chamber intake cap.
The boiler is made up of:
• total pre-mixing combustion system with steel multigas burner,
complete with ignition electrodes and ionisation control;
• pneumatic gas valve with double shutter;
• primary gas/water heat exchanger with casing in composite material
and stainless steel internal coil;
• combustion chamber in stainless steel internally isolated using
ceramic panels;
• fan for flue evacuation with electronically variable speed;
• circuit for disposal of condensate including trap and flexible di-
scharge pipe;
• secondary water/water exchanger for the production of domestic
hot water realised in stainless steel with 14 plates;
• hydraulic unit comprising a 3-way electric valve, an adjustable-speed
circulating pump with built-in air separator, automatic by-pass,
system flow switch, 3 bar safety valve for the primary circuit, a
system draining fitting and filling valve;
• domestic hot water flow switch for detection of withdrawal of
domestic hot water;
• 8 litre expansion vessel system with diaphragm (real 5.7) with pre-
load at 1.0 bar and manometer;
• water overheating safety thermostat, heat exchanger safety thermo-
fuse and flue safety thermofuse;
VICTRIX 26 2 I feaTuRes
- if installed using the vertical
/ C
53
83
VICTRIX 26 2 I
VICTRIX X 24 -12 2 I
VICTRIX 26 2 I is the wall-mounted, instant sealed chamber
boiler with heat output of 23.6 kW in central heating mode and
26 kW in domestic hot water mode which, thanks to condensation
technology, is characterised for its particularly high efficiency.
The innovative total premix combustion system and the special
environment-friendly burner mean it can run on natural or LPG
gas, guaranteeing extremely low pollutant emissions (VICTRIX
26 2 I boiler belongs to the most environment-friendly class
envisioned by European Standards - class 5). The boiler is cha-
racterised by its elegant Schumann design which together with its
compact size, make this boiler the ideal solution for integration in
kitchen wall units and small spaces and it also fits in with room
furnishings (only 25 cm depth). The boiler is also type-approved
for functioning outdoors in partially protected places (standard
anti-freeze protection -5°C, with optional kit for -15°C).
The new microprocessor-controlled electronics allows optimum
control of temperatures both in central heating and domestic hot
water production modes and it may also be coupled to the exclu-
sive Comando Amico Remoto remote control and to the external
probe (both optional features), which allow to manage, control
and program the boiler at a distance with extreme simplicity, thus
optimising functioning through climatic heat adjustment.
• central heating system temperature adjustment selector switch,
domestic hot water system temperature adjustment selector switch,
operation selector switch (Stand-by, Summer, Winter, Reset), digital
display;
• control panel with microprocessor P.C.B. with 2 sensor continuous
flame modulation (DHW and CH) with P.I.D. control, modulation
field from 23.6 to 3.0 kW (26 kW in DHW mode);
• CH temperature range selection 25 - 50°C or 25 - 85°C (setting as
per series);
• electronic ignition with ionisation control;
• ignition retarder in central heating mode, anti-freeze protection
system (to -5°C), pump anti-block device function, post-ventilation
function, chimney sweep function, pump functioning mode selec-
tion; preparation for connection to Immergas Comando Amico
Remoto remote control and timer thermostat, room thermostat,
external probe and control unit for area systems;
• self-diagnosis system with digital display of the temperature, fun-
ctioning mode and error codes by means of the back-lit display,
always available;
• IPX4D electrical insulation rating;
• possibility of coupling to the system for ducting of existing flues Ø
60 mm and Ø 80 mm;
• connection unit (optional) with depth-adjustable fittings on the
hydraulic attachments and gas and domestic cold water cut-off
cocks.
Supplied complete with sample points for combustion analysis, lower
protection sumps.
Category II appliance
+, functions with a natural gas and L.P.G.
2H3
CE Marking.
It is available in the model:
• VICTRIX 26 2 I
NOTa BeNe: for correct installation of the boiler the Immergas "Green
Range" air intake/flue exhaust kit must be used.
1
Wall-mounted condensing
code 3.019516

Advertisement

Table of Contents
loading

Summary of Contents for Immergas VICTRIX 26 2 I

  • Page 1 3 bar safety valve for the primary circuit, a NOTa BeNe: for correct installation of the boiler the Immergas "Green system draining fitting and filling valve; Range" air intake/flue exhaust kit must be used.
  • Page 2 • circuit for disposal of condensate including trap and flexible di- scharge pipe; • hydraulic unit comprising an adjustable-speed pump with built-in NOTa BeNe: for correct installation of the boiler the Immergas "Green air separator, automatic by-pass, system flow switch, 3 bar safety Range" air intake/flue exhaust kit must be used. valve for the primary circuit, ball valve for system filling;...
  • Page 3 (Stand-by, Summer, Winter, Reset), digital display; with nominal heat output of 12 kW with high-efficiency and fan- • control panel with microprocessor P.C.B. with continuous lame assisted circulation, prepared for coupling to a separate Immergas 80, modulation with P.I.D. control, modulation field from 12 kW to 105, 120 or 200 litre Storage Tank Unit for the production of domestic 1.9 kW;...
  • Page 4 VICTRIX 26 2 I VICTRIX X 24 -12 2 I VICTRIX 26 2 I maIN COmpONeNTs KeY: - Electric connection terminal board (very low voltage) - Condensate drain trap 18 - Negative signal pressure point - DHW heat exchanger 19 - Positive signal pressure point...
  • Page 5 VICTRIX 26 2 I VICTRIX X 24 -12 2 I VICTRIX X 24 2 I - X 12 2 I maIN COmpONeNTs KeY: - Electric connection terminal board (very low voltage) 16 - Flue safety thermofuse - System draining valve...
  • Page 6 VICTRIX 26 2 I VICTRIX X 24 -12 2 I VICTRIX 26 2 I maIN COmpONeNTs model Height mm Width mm Depth mm Ø intake/exhaust mm VICTRIX 26 2 I 100/60 6.1 CONNeCTIONs Casing upper line a = intake/exhaust B = intake Distance between casing upper line and Ø...
  • Page 7 VICTRIX 26 2 I VICTRIX X 24 -12 2 I VICTRIX X 24 2 I maIN DImeNsIONs model Height mm Width mm Depth mm Ø intake/exhaust mm VICTRIX X 24 2 I 100/60 7.1 CONNeCTIONs Casing upper line a = intake/exhaust B = intake Distance between the casing upper line and separator bend axis Ø...
  • Page 8 VICTRIX 26 2 I VICTRIX X 24 -12 2 I VICTRIX X 12 2 I maIN DImeNsIONs model Height mm Width mm Depth mm Ø intake/exhaust mm VICTRIX X 12 2 I 100/60 8.1 CONNeCTIONs Casing upper line a = intake/exhaust B = intake Distance between casing upper line and N.B.: Connection group (OPTIONAL)
  • Page 9 VICTRIX 26 2 I VICTRIX X 24 -12 2 I MAIN DIMENSIONS WITH OMNI CONTAINER KIT (OPTIONAL) code 3.016991 model Height mm Width mm Depth mm Ø intake/exhaust mm VICTRIX X 12 2 I with Omni Container kit 1190 100/60 9.1 CONNECTIONS WITH RECESS KIT (OPTIONAL) a = intake/exhaust B = intake  with the connection unit for recess installation N.B.: Connection group (OPTIONAL)
  • Page 10 VICTRIX 26 2 I VICTRIX X 24 -12 2 I sTORaGe TaNK uNIT maIN DImeNsIONs (OpTIONaL) 80 litre storage tank unit 105 litre storage tank unit 120 litre storage tank unit 200 litre storage tank unit Height mm 1020 1250 Width mm Depth mm 80 litre storage tank unit 105 litre storage tank unit 200 litre storage tank unit 102 litre storage tank unit...
  • Page 11 The by-pass can be excluded by acting on the relative screw pump is already fitted with a condenser. located on the front of the hydraulic unit. 11.1 VICTRIX 26 2 I - X 24 2 I pump GRUNDFOS UP 15-60 AO HB flow rate l/h 11.2...
  • Page 12 VICTRIX 26 2 I VICTRIX X 24 -12 2 I VICTRIX 26 2 I WIRING DIaGRam ROOm THeRmOsTaT OR RemOTe CONTROL The boiler is prepared for the application of the Room Ther- the boiler is prepared for the application of the Comando Ami-...
  • Page 13 VICTRIX 26 2 I VICTRIX X 24 -12 2 I VICTRIX X 12 2 I - X 24 2 I WIRING DIaGRam ROOm THeRmOsTaT OR RemOTe CONTROL The boiler is prepared for the application of the Room Ther- the boiler is prepared for the application of the Comando Ami-...
  • Page 14 VICTRIX 26 2 I VICTRIX X 24 -12 2 I VICTRIX 26 2 I HYDRauLIC DIaGRam KeY: - Condensate drain trap - Domestic hot water flow switch - Flow limiter - System filling valve 5 - Domestic hot water probe - Gas valve...
  • Page 15 VICTRIX 26 2 I VICTRIX X 24 -12 2 I VICTRIX X 12 2 I - X 24 2 I HYDRauLIC DIaGRam KeY: - Condensate drain trap - System filling valve - Gas valve - Gas valve outlet pressure point (P3)
  • Page 16 VICTRIX 26 2 I VICTRIX X 24 -12 2 I VICTRIX 26 2 I TeCHNICaL DaTa VICTRIX 26 2 I Domestic hot water maximum heating power kW (kcal/h) 26.7 (22,933) Central heating maximum heat input kW (kcal/h) 24.1 (20,747) DHW maximum useful heat output kW (kcal/h) 26.0 (22,360) CH maximum useful heat output kW (kcal/h) 23.6 (20,296)
  • Page 17 VICTRIX 26 2 I VICTRIX X 24 -12 2 I VICTRIX X 24 2 I TeCHNICaL DaTa VICTRIX X 24 2 I Central heating maximum heat input kW (kcal/h) 24.1 (20,747) Central heating maximum nominal heat output kW (kcal/h) 23.6 (20,296) Minimum nominal heat input kW (kcal/h) 3.2 (2,719) Minimum nominal heat output kW (kcal/h) 3.0 (2,580)
  • Page 18 VICTRIX 26 2 I VICTRIX X 24 -12 2 I VICTRIX X 12 2 I TeCHNICaL DaTa VICTRIX X 12 2 I Maximum nominal heat input kW (kcal/h) 12.3 (10,563) Maximum useful heat output kW (kcal/h) 12.0 (10,230) Minimum nominal heat input kW (kcal/h) 2.0 (1,753) Minimum nominal heat output kW (kcal/h) 1.9 (1,671) Efficiency at 100% Pn (80/60°C) 97.7...
  • Page 19 VICTRIX 26 2 I VICTRIX X 24 -12 2 I VICTRIX 26 2 I - X 24 2 I COmBusTION feaTuRes Methane (G20) LPG (G30) LpG (G31) Combustion efficiency 100% Pn (80/60°C) 98.0 98.0 98.0 Combustion efficiency P min (80/60°C) 97.8 97.8 97.8 Useful efficiency at 100% Pn (80/60°C) 97.8 97.8 97.8 Useful efficiency P min (80/60°C) 94.9 94.9 94.9...
  • Page 20 VICTRIX 26 2 I VICTRIX X 24 -12 2 I VICTRIX X 12 2 I COmBusTION feaTuRes Methane (G20) LPG (G30) LpG (G31) Combustion efficiency 100% Pn (80/60°C) 98.0 98.0 98.0 Combustion efficiency P min (80/60°C) 97.8 97.8 97.8 Useful efficiency at 100% Pn (80/60°C) 97.7 97.7 97.7 Useful efficiency P min (80/60°C) 93.2 93.2 93.2 Useful efficiency at 100% Pn (50/30°C) 106.9 106.9 106.9...
  • Page 21 VICTRIX 26 2 I VICTRIX X 24 -12 2 I VICTRIX 26 2 I OpTIONaLs super Comando amico Remoto remote control Comando amico Remoto remote control code 3.016577 code 3.011236 Telephone control external probe code 3.013305 code 3.014083 Digital weekly timer-thermostat Radio timer-thermostat (wireless) code 3.014438...
  • Page 22 VICTRIX 26 2 I VICTRIX X 24 -12 2 I VICTRIX X 12 2 I - X 24 2 I OpTIONaLs super Comando amico Remoto remote control Comando amico Remoto remote control code 3.016577 code 3.011236 Zones control unit kit external probe code 3.011668...

This manual is also suitable for:

Victrix x 12 2 iVictrix x 24 2 i

Table of Contents