1 binary input circuit
Binary input BE2: Terminals 11 and 12, terminals 21 and 22 (jumper)
Galvanically connected with the
basic device
Signal status 0
Signal status 1
Contact load
Electrically isolated from the basic
device
Signal status 0
Signal status 1
Internal resistance
Static destruction limit
Connecting to circuits with the
following peak values
Effective internal capacitance
Effective internal inductance
Galvanic isolation
Test voltage
SIPART PS2 with and without HART
Operating Instructions, 10/2013, A5E00074631-11
Without Ex protection/
with Ex protection Ex d
± 35 V
-
-
-
The three outputs, the BE2 input and the basic device are galvanically isolated
With Ex protection Ex "ia"
Floating contact, open
Floating contact, closed
3 V, 5 μA
≤ 4.5 V or open
≥ 13 V
≥ 25 kΩ
-
U
= DC 25.2 V
i
C
= negligibly small
i
L
= negligibly small
i
from each other.
DC 840 V, 1 s
Technical data
12.8 Option modules
With Ex protection
Ex "ic", "nA", "t"
-
"ic":
U
= DC 25.2 V
i
"n"/"t":
U
≤ DC 25.5 V
n
C
= negligibly small
i
L
= negligibly small
i