Instruction Data | 350A-1 | 360A-1 | 550A-3 | 560A-3
Product: 350A-1, 350A-2, 360A-1, 360A-2, 750A-1, 760A-1,
550A-3, 550A-4, 560A-3, 560A-4 Two wire
energysense
Master push button and touch timer
Rating at 240V ac
• Incandescent 16A • Compact Fluorescent 16A
ene rgystyle
• Resistive
16A • Fluorescent 16A • Time Delay 2min - 2h
Fitting and operating instructions – Two wire (Lin-Lout). For lighting only
The pushbutton/touch timer are part of the Elkay family of
energyo utdoor
switches, timers and detectors which save energy and increase
convenience in and around your home, garden or premises.

Usage

The push button/touch timer are general purpose time controls.
Applications for suitable use include lighting and some heating
and ventilation controls. The timers can be used independently or
as a master unit when using slave trigger switches. One master
product only for each circuit being switched with additional slave
units at other positions in the circuit.
WHEN USED WITH SOME LOW WATTAGE LIGHTING,
HEATING AND VENTILATION CIRCUITS PLEASE ENSURE A
CAPACITOR OF 2 MICROFARADS (MINIMUM) IS FITTED.
SUPPLIES OF SUITABLE ELKAY CAPACITORS CAN BE FOUND
AT YOUR STOCKIST (REF PFCC-1)
Pushbutton
IMPORTANT Please note that it is essential that the live in and
Push Button Master
live out are identified prior to commencing the installation
and steps 1 – 3 are followed precisely. No neutral is required on
this product (See diagram 1). Do not install the switch timer
Diagram 1
with the mains power on as this can damage the product.

Features

Wiring diagram for a single sensor unit.
Time Delay: 2min-2hr
NOT SUITABLE FOR USE WITH CONTACTORS. DO NOT MEGGER
Voltage: 240Va.c. 50Hz
TEST OR INSULATION RESISTANCE TEST THIS PRODUCT.
REMOVE BEFORE TESTING OR TEST CIRCUIT PRIOR TO FITTING.
Load Rating & Type: 16A for all lighting loads that are LED,
Compact Fluorescent and Fluorescent, Incandescent and
Your Elkay unit is compatible with a single gang, 25mm deep
Resistive.
British Standard accessory plate. Please ensure that the
(This Push button and touch timer cannot be used on contactors.
top and bottom lugs are removed from metal wall boxes
Please use Elkay three wire Master timers
prior to fitting. For 16mm boxes Elkay provide a spacer plate
and sensors)
(product code220A-1) to take box depth to 25mm.
Slave fitting
The pushbutton/touch timers are part of the Elkay family of
When connecting with slaves use three core cable connecting the
live in, live out and trigger terminals as shown in Diagram 2. The
switches, timers and detectors which save energy and increase
optional wire to the slaves only applies to the 350A and 550A
convenience in and around your home, garden or premises.
push button slave units and is ideal for retrofitting (See diagram 2).
Usage
The push button/touch timers are general purpose time controls.
Applications for suitable use include lighting and fans with
IMPORTANT NOTICE
lighting.The timers can be used independently or as a master unit
All wiring should be carried out by a competent person or a qualified electrician and should be fitted to IEE 17th Edition Wiring regulations BS7671:2008.
when using slave trigger switches. One master product only for
Please note that the trigger terminal is the third terminal. This
each circuit being switched with additional slave units at other
product requires a 24 hour power supply. The battery inside the
positions in the circuit.
unit recharges when the light source or appliance is switched
When used with some low wattage lighting, low voltage
OFF. Where the supply may be interrupted or isolated regularly
lighting, LED fittings and 2D flouresecents, please ensure
we must recommend our products from the three wire range.
a capacitor of 4 microfarads is fitted at the load across the
switch live and neutral. Only one is required per circuit.
Supplies of suitable Elkay capacitors can be found at your
DO NOT APPLY MAINS UNTIL INSTRUCTED!
local stockist (ref PFCC-1).
Step 1 - Ensure that the mains power to the circuit is switched off.
IMPORTANT Please note that it is essential that the live in and
Place the previously identified Live In into the terminal marked L In
live out are identified prior to commencing the installation and
and the switched Live Out into the L Out terminal.
steps 1 – 3 are followed precisely. No neutral is required on this
Step 2 - Switch the battery (switch 4) – you will notice a red LED
product (See diagram 1). Do not install the switch timer with the
light flashing on the front of the unit- which will be flashing
mains power on as this can damage the product.
rapidly. Whilst this is in action please select the desired timings
by selecting the appropriate time settings shown in diagram 3.
Do not megger test or insulation resistance test this product.
Remove before testing or test circuit prior to fitting.
Please ensure that when emergency fittings are tested for
3 hr test that battery switch number 4 on the product is
switched off first and switched back on after test.
Touch
Touch Master
LIVE IN
NEUTRAL
LIVE OUT
Battery
4.
3.
2.
1.
Lux level
DIL
adjustment
switches
Call +44 (0) 1675 468222 or click www.elkay.co.uk
energyo utdoor
Pushbutton
Diagram 1
Diagram 1
Wiring diagram for a single sensor unit.
8526 PUSH BUT & TOUCH INSTRUCTIONSv3_Layout 1 25/02/2010
adjustment
pushbutton & touchsenso
pushbutton & touchsensor fitting and operating instructi
Diagram 2
Please note that the trigger terminal is the third terminal. This
product requires a 24 hour power supply. The battery inside the
Wiring diagram for a sensor unit with slave.
unit recharges when the light source or appliance is switched
OFF. Where the supply may be interrupted or isolated regularly
we must recommend our products from the three wire range.
Installation Steps
DO NOT APPLY MAINS UNTIL INSTRUCTED!
Battery
Step 1 - Ensure that the mains power to the circuit is switched off.
4.
3.
2.
1.
Place the previously identified Live In into the terminal marked L In
Lux level
DIL
adjustment
switches
and the switched Live Out into the L Out terminal.
Step 2 - Switch the battery (switch 4) – you will notice a red LED
light flashing on the front of the unit- which will be flashing
rapidly. Whilst this is in action please select the desired timings
by selecting the appropriate time settings shown in diagram 3.
Master
Step 3 - Attach the unit with the screws to the wall, then clip
350A-1*
on the front fascia plate. The red LED light will now change to a
360A-1
single flashing light every 3 seconds approximately. You are now
550A-3*
ready to apply the mains power. The light or chosen appliance
560A-3
will now start. Press and hold the button, the red flashing light
goes off and the blue locator ring will light up around the
push button/touch pad. Your light source or appliance will
Slave & Momentary Fitting
now be switched off and ready for operation.
When connecting with slaves use three core cable connecting
the live in, live out and trigger terminals as shown in Diagram 2.
The optional wire to the slaves only applies to the 350A and 550A
1.
Press the pushbutton/touch pad and the red LED will light
push button slave units and is ideal for retrofitting (See diagram 2).
once. Your light source or appliance will now be switched
on. Please note that the pushbutton has an audible click.
Please note that the trigger terminal is the third terminal.
2.
At any time during the working of the light source or
Momentary or activating switches can also be used and can be
appliance, the push button/touch pad can be pressed to
connected to the Live In and the Trigger terminal of the master.
reset the timing sequence to the originally set time,
This product requires a 24 hour power supply. The battery inside
e.g when the timing period is 30 minutes, if pressed 15 minutes
the unit recharges when the light source or appliance is switched
into the sequence, the timer will reset to 30 minutes.
OFF. Where the supply may be interrupted or isolated regularly we
3.
To end the timing sequence prematurely, press and hold the
must recommend our products from the three wire range.
push button/touch pad until the red LED flashes
Your Elkay unit is compatible with a single gang, 25mm deep
British Standard accessory plate. Please ensure that the top and
bottom lugs are removed from metal wall boxes prior to fitting. For
16mm boxes Elkay provide a spacer plate (product code 220A-1)
to take box depth to 25mm.
4.
3.
2.
1.
2 mins
For further wiring diagrams and more information on our products ple
Touch
LIVE IN
NEUTRAL
LIVE OUT
Battery
4.
3.
2.
1.
Lux level
DIL
switches
Diagram 2
*Optional wire for blue indicator
*Optional wire for blue indicator
LIVE IN
ring on push button slaves only
NEUTRAL
ring on push button slaves only
LIVE OUT
Slave
350A-3*
360A-3
550A-5*
560A-5
Diagram 3 - time settings
Please note that the black bar denotes the position of
4.
4.
3.
3.
2.
2.
1.
1.
5 mins
10 mins
continuo
operatio
switched
4.
At one m
red LED
of opera
the light
Operation N
If the Elkay Tim
the unit into s
the unit press
the red LED sh
to a flash ever
off. The unit w
automatically
Outdoor Inst
Please note on
suitable for us
in conjunction
surface moun
and to ensure
cable gland an
surface moun
supplied. Plac
essential that
the IP66 rating
without seals
Turn off main
as per previou
onto surface
ensuring even
over left and
Re-instate ma
4.
4.
3.
3.
2.
2.
1.
1.
20 mins
40 mins

Advertisement

loading

Summary of Contents for Elkay 350A-1

  • Page 1 & touchsensor fitting and operating instructions yout 1 25/02/2010 14:43 Page 1 pushbutton/touchsensor master unit - two wire Instruction Data | 350A-1 | 360A-1 | 550A-3 | 560A-3 Product: 350A-1, 350A-2, 360A-1, 360A-2, 750A-1, 760A-1, 550A-3, 550A-4, 560A-3, 560A-4 Two wire energysense...
  • Page 2 Place the previously identifi ed Live In into the terminal marked For further help or assistance or information on this or other products in the range please call the Elkay Technical team on 01675 468222. before going to sleep mode as mentioned above . To manually Please call the Technical helpline before returning any products to your stockist.

This manual is also suitable for: