slaveswitch
slaveswitch fitting & operating instructions
The slave switch is part of the Elkay family of switches, timers and detectors which save
energy and increase convenience in and around your home, garden or premises.
USAGE
The slave units work in conjunction with all master timers to remotely
trigger the timing. Any combination of slaves can be wired to any
master, thus giving a variety of activation functions in one area all
operating one central timer.
All slave units are designed to control lighting, heating and ventilation.
POSITIONING – PIR SLAVE
Use the detection range to determine a suitable location for the PIR
sensor. When locating the position of the unit avoid subjecting the
sensor to direct sunlight. Ensure that the sensor is not adjacent to the
load. Do not site unit a vibrating surface or near a forced air heating
or ventilation.
MOUNTING AND INSTALLATION
Important Please note that it is essential that the Live In wire and switch Live Out is identified prior to commencing
installation. Turn off mains supply before installation. Your Elkay unit is compatible with a single gang, 25mm deep, British
standard accessory plate. Please ensure that the top and bottom lugs are removed, if fitted, from metal wall boxes prior to
fitting. Ensure that there is adequate space for wiring.
Step 1 Please select wiring diagram as per combination of master and slave unit, by checking your individual part number
and then wire as per correct diagram.
Step 2 On touch button and PIR slave, the battery jumper is located in the top right hand corner and must be fixed on the
two upper terminals.
OFF
ON
Step 3 On the PIR slave, ensure that the lux level adjustment has been adjusted to the desired level via the rotary lux level
adjuster. The mains supply must be disconnected before the lux level is adjusted. Please ensure that an insulated screwdriver
is used for lux level adjustment.
Step 4 Timing should be set on the master unit as per its individual instructions.
INSTALLATION NOTES
N.B After installation the PIR will require approximately 5 minutes to initialise.
Elkay Electrical, Coleshill, Birmingham, England.
Tel: +44 (0) 1675 468222 www.elkay.co.uk
RATING AT 240V AC
Incandescent 16A
Fluorescent
16A
Compact
16A
Fluorescent
Resistive
16A
Time Delay
2mins - 2hours.
5 - 7m
5 - 7m
Patent Pending Inst. Ref. No SLA01 Rev. No.: 11/07