7.3.8 Start Concurrent Measurement with CRC (aCC)
Command format:
aCCx!
Use this command when there are several devices on the same bus and simultaneous
measurements are needed from the devices but a three-character CRC is added to the
response data strings before <cr><lf>.
To request the measured data, use the Send data command aD.
7.3.9 Send Data Command (aD)
Use this command to request the measured data from the device.
Start measurement command indicates the number of parameters available. The number
of the parameters that can be included in a single message depends on the number of
characters in the data fields. If not all the parameters are retrieved in a single response
message, repeat the Send data commands until all the data is obtained.
Command format:
aDx!
a
D
x
!
Response:
a+<data fields><cr><lf>
a
<data fields>
sales@streamlinemeasurement.co.uk
Device address
Send data command
The order of consecutive Send data commands. Make sure the first Send data
command is addressed with x=0. If all the parameters are not retrieved, send
the next Send data command with x=1 and so on. The maximum value for x is 9.
Command terminator
Device address
The measured parameters in selected units, separated with '+' marks (or - marks
in case of negative parameter values).
01457-864334
Chapter 7 – Retrieving Data Messages
www.streamlinemeasurement.co.uk