OPERATING INSTRUCTIONS

®
3491 Mission Oaks Blvd., Camarillo, CA 93011
Visit our Web site at: http://www.harborfreight.com
TO PREVENT SERIOUS INJURY,
READ AND UNDERSTAND ALL WARNINGS
AND INSTRUCTIONS BEFORE USE.
Copyright 2004 by Harbor Freight Tools
©
®
. All rights reserved. No portion of this
manual or any artwork contained herein may be reproduced in any shape or form
without the express written consent of Harbor Freight Tools.
For technical questions or replacement parts, please call 1-800-444-3353.

Advertisement

Table of Contents
loading

Summary of Contents for Chicago Electric 92465

  • Page 1: Operating Instructions

    MULTI-FUNCTION JUMP STARTER Model 92465 OPERATING INSTRUCTIONS ® 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at: http://www.harborfreight.com TO PREVENT SERIOUS INJURY, READ AND UNDERSTAND ALL WARNINGS AND INSTRUCTIONS BEFORE USE. Copyright 2004 by Harbor Freight Tools ©...
  • Page 2: Product Specifications

    IMPORTANT SAFETY INSTRUCTIONS WARNING! READ AND UNDERSTAND ALL INSTRUCTIONS Failure to follow all instructions listed in the following pages may result in electric shock, fire, and/or serious injury. SAVE THESE INSTRUCTIONS SKU 92465 For technical questions, please call 1-800-444-3353 PAGE 2...
  • Page 3: Work Area

    Do not use small equipment, tools, or attachments to do the work of larger industrial equipment, tools, or attachments. Do not use this product for a purpose for which it was not intended. SKU 92465 For technical questions, please call 1-800-444-3353 PAGE 3...
  • Page 4: Specific Safety Rules

    Do not use the Jump Starter in areas near flammable chemicals, dusts, and vapors. Maintain labels and nameplates on the Jump Starter. These carry important SKU 92465 For technical questions, please call 1-800-444-3353 PAGE 4...
  • Page 5 Red Battery Clamp first, then connect the Black Battery Clamp. When disconnecting the Battery Clamps, always disconnect the Black Battery Clamp first, then disconnect the Red Battery Clamp. SKU 92465 For technical questions, please call 1-800-444-3353 PAGE 5...
  • Page 6 Normal charging time for the Battery is 20-24 hours. Never charge the Battery for over 24 hours. To insure safe operation, check periodically on the progress of the battery charge. Never leave this product unattended for the full length of the charge. SKU 92465 For technical questions, please call 1-800-444-3353 PAGE 6...
  • Page 7: Product Features

    21. Cable Compartment Door 22. Battery (Not Shown) 23. 12 VDC Cigarette Lighter Adapter 24. AC/DC Charger 25. Hazard Light Lens 26. Fluorescent Lamp Lens 27. Spotlight Lens FIGURE A SKU 92465 For technical questions, please call 1-800-444-3353 PAGE 7...
  • Page 8 GREEN LIGHT = 3/4 CHARGED replace the Battery (22). Battery replacement should YELLOW LIGHT = 1/2 CHARGED only be done by a qualified RED LIGHT = DISCHARGED service technician. FIGURE B SKU 92465 For technical questions, please call 1-800-444-3353 PAGE 8...
  • Page 9 (8). Then, unplug the Charging Plug of the Cigarette Lighter Adapter from the power input socket of the tool or appliance. (See Figure A.) As soon as possible, recharge the Jump Starter. SKU 92465 For technical questions, please call 1-800-444-3353 PAGE 9...
  • Page 10 Air Hose (20). (See Figure A.) If inflating a tire, make sure the Lever of the Air Hose (2) is in its vertical position. (See Figure C.) AIR HOSE LEVER UNIVERSAL HOSE ADAPTER FIGURE C SKU 92465 For technical questions, please call 1-800-444-3353 PAGE 10...
  • Page 11 Turn the Compressor Switch (4) to its “ON” position to turn on the Air Compres- sor. Compressed air will begin to flow from the Air Compressor into the object being inflated. (See Figure A.) SKU 92465 For technical questions, please call 1-800-444-3353 PAGE 11...
  • Page 12 The Spotlight Switch (5) controls the Spotlight Bulb (15). Turn the Spotlight Switch to its “ON” position to turn on the Spotlight. Turn the Spotlight Switch to its “OFF” position to turn off the Spotlight. (See Figure A.) SKU 92465 For technical questions, please call 1-800-444-3353 PAGE 12...
  • Page 13 Jump Starter or if the temperature exceeds 150 Fahrenheit. An internal audible alarm will also sound. Make sure the ventilation fan vents are not blocked, and allow the unit to cool before restarting the Power Inverter. (See Figure A.) SKU 92465 For technical questions, please call 1-800-444-3353 PAGE 13...
  • Page 14: Inspection, Maintenance, And Cleaning

    (27) to expose the Spotlight Bulb. Push in and turn the Spotlight Bulb to release REFLECTOR BOWL HAZARD SCREW LIGHT BULB (13) SPOTLIGHT BULB (15) FLUORESCENT FLUORESCENT LAMPS LAMP LENS (14) (26) SPOTLIGHT LENS HAZARD (27) LIGHT LENS (25) FIGURE F SCREW SKU 92465 For technical questions, please call 1-800-444-3353 PAGE 14...
  • Page 15: Please Read The Following Carefully

    RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO. Note: No replacement parts are available. SKU 92465 For technical questions, please call 1-800-444-3353 PAGE 15...