Teledyne Lecroy WaveSurfer 510 Getting Started Manual

Teledyne Lecroy WaveSurfer 510 Getting Started Manual

Hide thumbs Also See for WaveSurfer 510:

Advertisement

Quick Links

WaveSurfer 510
Oscilloscopes
Getting Started Guide

Advertisement

Table of Contents
loading

Summary of Contents for Teledyne Lecroy WaveSurfer 510

  • Page 1 WaveSurfer 510 Oscilloscopes Getting Started Guide...
  • Page 4: Table Of Contents

    Welcome Thank you for buying a Teledyne LeCroy product. We’re certain you’ll be pleased with the detailed features so unique to our instruments. This Getting Started Guide is designed to cover important safety and installation information for your oscilloscope, along with some basic operating procedures so you’re quickly working with waveforms.
  • Page 5 INTRODUCTION WaveSurfer 510 Oscilloscopes...
  • Page 6: Introduction

    INTRODUCTION About the WaveSurfer 510 Oscilloscopes Comprehensive Analysis Tools The WaveSurfer 510 combines the MAUI advanced user interface with high performance 10 GS/s hardware, powerful waveform processing, and WaveSurfer 510 has one of the most comprehensive trigger, decode, advanced math, measurement and debug tools to quickly analyze and math, measurement and application toolsets available.
  • Page 7: Specifications

    Specifications Materials List Detailed specifications are maintained in the Datasheet on the product Check that you have all the parts listed here. Contact Teledyne page at teledynelecroy.com. LeCroy immediately if any part is missing. • 1 oscilloscope Key Specifications • 4 passive probes •...
  • Page 8: General Safety Information

    INTRODUCTION General Safety Information Precautions • Use proper power cord. Use only the power cord shipped with this This section contains instructions that must be observed to keep the instrument and certified for the country of use. instrument operating in a correct and safe condition. You are required to follow generally accepted safety procedures in addition to the precautions •...
  • Page 9 Operational Environment Cleaning Temperature: 5° to 40° C Clean only the exterior of the oscilloscope using a damp, soft cloth. Do Humidity: Maximum relative humidity 90% for temperatures up to not use harsh chemicals or abrasive elements. Under no circumstances 31°...
  • Page 10: Support

    Manuals, tutorials, application notes, white papers, and videos are Calibrate All calibrates all possible combinations of vertical and available to help you get the most out of your Teledyne LeCroy products. horizontal settings. This calibration is valid for the current temperature and takes about four to five hours.
  • Page 11 SET UP WaveSurfer 510 Oscilloscopes...
  • Page 12: Set Up

    SET UP The Front of Your Oscilloscope Touch Screen Display Front Panel Built-in Stylus Holder Power Button Channel Inputs EXT Input Aux Output USB 2.0 Port Ground and Calibration Output Terminals LBUS Interface Tilting Feet...
  • Page 13 Ground and calibration output terminals are used to compensate controls, touch screen soft controls, or a mix of both that is convenient passive probes. WaveSurfer 510 oscilloscopes are compatible with the for you. See “Front Panel” on p.26 for more information.
  • Page 14: The Side Of Your Oscilloscope

    SET UP The Side of Your Oscilloscope HDMI Port (1) for external monitor DisplayPort Port (1) for external monitor USB 3.1 Ports (4) Ethernet Ports (2) for LAN connection or remote control Audio In/Out: Mic and Speaker...
  • Page 15: Connecting

    Fujitsu drivers cannot be used Printer as touch screens, only as displays. WaveSurfer 510 supports USB printers that are compatible with the Windows OS installed on the oscilloscope. Connect the printer to any host Auxiliary Output USB port, then go to File>...
  • Page 16: The Back Of Your Oscilloscope

    SET UP The Back of Your Oscilloscope Built-in Carrying Handle AC Power Inlet for the AC line cord Kensington Lock...
  • Page 17: Powering On/Off

    Powering On/Off Language Selection Connect the line cord rated for your country to the AC power inlet on the To change the language that appears on the display, go to Utilities > back of the instrument, then plug it into a grounded AC power outlet. Preference Setup >...
  • Page 18: Software Activation

    Software Activation Firmware Updates The oscilloscope operating software (firmware and standard applications) Free firmware updates are available periodically from the Teledyne LeCroy is active upon delivery. website at teledynelecroy.com/support/softwaredownload. Registered users will receive email notification when a new update is released. To...
  • Page 19: User Interface

    USER INTERFACE WaveSurfer 510 Oscilloscopes...
  • Page 20: Touch Screen Display

    USER INTERFACE Touch Screen Display The entire display is a touch screen. Use your finger or the stylus to touch, drag-and-drop, swipe, pinch, and flick. Many controls that display information also work as “buttons” to access other functions. If you have a mouse installed, you can click anywhere you can touch to activate a control; in fact, you can alternate between clicking and touching, whichever is convenient for you.
  • Page 21 A toolbar along the bottom of the main Channel, Math, Memory and A drop-down menu bar lets you access set up dialogs and other Digital dialogs applies common actions so that you don’t have to leave functions. All functionality can be accessed through either the menu bar the underlying dialog.
  • Page 22: Changing The Display

    USER INTERFACE Changing the Display By default, the oscilloscope has the Auto grid mode enabled. Auto adds a The grid is 8 Vertical divisions representing 256 Vertical levels and 10 separate grid for channels, zooms, and math functions/memories. Other grid Horizontal divisions.
  • Page 23 Using WaveStream Line and Intensity The trace style can be set to a series of separate WaveStream provides a vibrant, intensity graded display with a sample Points or a continuous vector Line. fast update rate to closely simulate the look and feel of an analog oscilloscope.
  • Page 24: Working With Traces

    USER INTERFACE Working With Traces Adjusting Trace Descriptor Boxes On setup dialogs, many entries can be made by selecting from the pop- Channel (C1-C4), Zoom (Z1-Z8), Math (F1-F8), Memory (M1-M4), and up menu that appears when you touch a control. But when an entry field Digital (Digital1-Digital4, on -MS models) descriptor boxes appear along appears highlighted in blue after touching, it is active and the value can be the bottom of the grid area when a trace is turned on.
  • Page 25: Maui With Onetouch

    MAUI with OneTouch Touch, drag, swipe, pinch, and flick can be used to create and change setups with one touch. Just as you change the display by using the setup dialogs, you can change the setups by moving different display objects. Use the setup dialogs to refine OneTouch gestures to precise values. As you drag &...
  • Page 26 USER INTERFACE Copy Setups Change Source To copy the setup of one trace to another of the same type (e.g., channel to To change the source of a trace, drag-and-drop the descriptor box of the channel, math to math), drag-and-drop the source descriptor box onto the desired source onto the target descriptor box.
  • Page 27 Position Cursors Change Trigger To change cursor measurement time/level, drag cursor markers to new To change the trigger level, drag the Trigger Level indicator to a new position positions on the grid. The cursor readout will update immediately. on the Y axis. The Trigger descriptor box will show the new voltage Level. To place horizontal cursors on zooms or other calculated traces where the Horizontal Scale has forced cursors off the grid, drag the cursor readout from below the Timebase descriptor to the grid where you wish to place the...
  • Page 28 USER INTERFACE Store to Memory To store a trace to internal memory, drag-and-drop its trace descriptor box To pan a trace, activate it to bring it to the forefront, then drag the waveform onto the target memory (Mx) descriptor box. trace right/left or up/down.
  • Page 29 Zoom Turn Off To create a new zoom trace, touch then drag To turn off a trace, flick the trace descriptor box toward the bottom of diagonally to draw a selection box around the the screen. portion of the trace you want to zoom. Touch the Zx descriptor box to open the zoom factor controls and adjust the zoom exactly.
  • Page 30: Front Panel

    Most of the front panel controls duplicate functionality available through the touch screen display. They are covered in more detail in the Basics section and in the WaveSurfer 510 Oscilloscopes Operator’s Manual. Below are some special front panel controls. Auto Setup turns on and configures all channels with a signal attached.
  • Page 31: Basics

    BASICS WaveSurfer 510 Oscilloscopes REFERENCE...
  • Page 32: Vertical

    BASICS Vertical These controls adjust the channel trace along the Y axis. From the Front Panel Analog Traces From the Display Drag another channel descriptor to the Add New box, or touch the Add New box and choose Channel. Press to turn on/activate analog trace. Turn to raise or lower Offset (analog) or Vertical Position (digital).
  • Page 33 Digital Traces From the Display Choose a standard Choose Vertical > Digital # Setup. Logic Family, or Touch Digital descriptor to open the enter custom values Digital dialog. for Threshold and Hysteresis. Separate controls allow you to set different values for each bank.
  • Page 34: Horizontal (Timebase)

    BASICS Horizontal (Timebase) These controls adjust the trace along the X axis. From the Front Panel From the Display Touch the Timebase descriptor Turn to increase or decrease trigger Delay. Push to box to open the Timebase dialog. return Delay to zero. Turn to raise or lower Horizontal Scale (Time/div).
  • Page 35: Triggers

    From the Display Triggers tell the oscilloscope when to perform an acquisition. Available trigger types are described at more length in the Touch Trigger WaveSurfer 510 Oscilloscopes Operator’s Manual. descriptor box to open the Trigger dialog. From the Front Panel Press to open the Trigger setup dialog.
  • Page 36: Cursors

    BASICS Cursors Cursors set measurement points on a trace. There are five preset cursor From the Display types, each with a unique appearance on the display: Horizontal (Time), Horizontal + Vertical, Vertical (Amplitude), Horizontal (Frequency), and Horizontal (Event). These are described in more detail in the WaveSurfer 510 Oscilloscopes Operator’s Manual.
  • Page 37: Measurements & Statistics

    Measurements & Statistics Measurements are waveform parameters that can be expressed as numerical values, such as amplitude or frequency. You can set up to six simultaneous measurements on one or more traces and view the active readout in a table. Statistical measurements can be added to the readout, along with histicons, a miniature histogram of the statistical distribution.
  • Page 38: Math

    BASICS Math Math traces display the result of applying a mathematical function (e.g., Average, FFT, Histogram) to one or more traces. One important distinction between math functions and measurement parameters is that the result of math is always another waveform trace, whereas the result of measurement is a number.
  • Page 39: Memories (Reference Waveforms)

    Memories (Reference Waveforms) To store a new memory, either: Memories are waveform traces stored for reference. They can be recalled to the display for comparison with other traces, or they can be zoomed and measured for better analysis of historical data. You can store up to Touch the Add New box and four internal memories (M1-M4).
  • Page 40: Decode

    BASICS Decode The Decode front panel button is activated when serial trigger and decode software options are installed. Press it to open the serial decode dialogs. Decoders apply software algorithms to extract encoded serial data information from physical layer waveforms measured on your oscilloscope. The extracted information is displayed over the waveforms, color-coded to provide fast, intuitive understanding of the relationship between protocol and signal.
  • Page 41: Wavescan

    WaveScan Press the WaveScan front panel button to open the WaveScan dialogs. WaveScan Search and Find enables you to search for unusual events in a single capture, or to scan for a particular event in many acquisitions over a long period of time. A predefined set of scan modes (similar to trigger setups) enable a quick search for events of interest.
  • Page 42: History Mode

    BASICS History Mode The History front panel button puts the instrument into History Mode. History Mode allows you to review any acquisition saved in the oscilloscope’s history buffer, which automatically stores all acquisition records until full. Not only can individual acquisitions be restored to the grid, you can “scroll” backward and forward through the history at varying speeds to capture details and changes in the waveforms over time.
  • Page 43: Saving And Sharing Data

    Setup, Waveform and Table Data Use the oscilloscope File menu options to save and recall data. See the WaveSurfer 510 Oscilloscopes Operator’s Manual for more information on The current oscilloscope configuration can be saved to internal setup using these features.
  • Page 44: Software Options

    BASICS Software Options These are just some of the options available to enhance the performance of a WaveSurfer 510. Spectrum Analyzer Software (WS510-SPECTRUM) simplifies setup and use of the oscilloscope for analyzing frequency-dependent effects. It allows users who are familiar with RF spectrum analyzers to start using the FFT with little or no concern about the details of setting up an FFT.
  • Page 45 BASICS REFERENCE WaveSurfer 510 Oscilloscopes...
  • Page 46: Reference

    1. Remove all accessories from the device. Do not include the manual. Service Centers 2. Pack the product in its case, surrounded by the original packing For a complete list of Teledyne LeCroy offices by country, including material (or equivalent). our sales and distribution partners, visit: teledynelecroy.com/support/ contact 3.
  • Page 47: Certifications

    1 To ensure compliance with all applicable EMC standards, use high-quality shielded interface cables. Teledyne LeCroy certifies compliance to the following standards as of 2 Emissions which exceed the levels required by this standard may occur when the instrument is the time of publication.
  • Page 48 For more information about proper disposal and recycling of your • Teledyne LeCroy product, please visit teledynelecroy.com/recycle. Measuring Circuit Terminals: No rated measurement category. Terminals not intended to be connected directly to the mains supply. RESTRICTION OF HAZARDOUS SUBSTANCES (RoHS) •...
  • Page 49: Warranty

    Intellectual Property The oscilloscope is warranted for normal use and operation, within All patents pertaining to the WaveSurfer 510 can be found on our website specifications, for a period of three years from shipment. Teledyne LeCroy will either repair or, at our option, replace any product returned to one of our authorized service centers within this period.