PROT: The protocol type to which the port is set:
 
For a SolarEdge device:
 
o
RS485 protocol
For electricity meters,   r efer to the application note - Connecting an Electricity Meter 
 
o
to SolarEdge Devices at http://www.solaredge.com/files/pdfs/solaredge-meter-
installation-guide.pdf.
SS: SunSpec - for a non-SolarEdge logger (monitoring and control)
 
o

Smart Energy Management Status

This screen is displayed only when Smart Energy Management is enabled. The screen shows energy details 
of the site:
S i t e
L i m i t :
S i t e
P r o d :
S i t e
E x p o r t :
S e l f - c o n s u m e :
Site Limit: The limit that was defined for the site
 
Site Prod: The power produced by the site
 
Site Export: The power that is fed into the grid
 
Self-consume: The PV power consumed by the site
 
For more information, refer to the Export Limitation Application Note, available on the 
SolarEdge website at http://www.solaredge.com/files/pdfs/products/feed-in_limitation_
application_note.pdf.

Power Control Status

This screen is displayed only when Power Control is enabled (available from 
communication board (CPU) firmware version 2.7xx/3.7xx and later).
P W R
C T R L :
P W R
L i m i t :
C o s P h i :
P o w e r
P r o d :
 
PWR CTRL: The power control status: 
 
REMOTE - Communication with the RRCR or smart energy manager is confirmed/validated. 
 
o
LOCAL - The power is controlled locally (e.g. by a fixed limit), or this inverter limits the PV power 
 
o
production to its relative portion of the feed-in power limit, as a result of disconnected 
communication with the smart energy manager. If this status appears, check the communication 
to the smart energy manager or the communication to the meter. 
StorEdge Inverter Installation Guide MAN-01-00390-1.1
S: SolarEdge slave
M: SolarEdge master
P2P: ZigBee point-to-point
MPM: ZigBee multipoint master (for the SolarEdge ZigBee
home gateway or for load management by the inverter)
MPS: ZigBee multipoint slave (for a ZigBee router card)
7 . 0 k W
1 0 . 0 k W
4 . 0 k W
6 . 0 k W
R E M O T E
1 0 . 0 4
k W
0 . 9
7 0 0 0 W
Chapter 6: User Interface
ZigBee protocol
67