CPU: The communication board firmware version
Country: the current country setting
Server Communication Status
S e r v e r : L A N
S t a t u s :
x x x x x x x x
< E R R O R
NOTE
If the connection method is CDMA (referred to as "Cellular" in the status screens) or GSM, the server
screen is replaced with the Cellular or GSM status screens (see Status Screens - Operational Mode on
page 63 and GSM Status on page 66).
Server: The method of connection to the SolarEdge monitoring platform.
S_OK: The connection to the SolarEdge monitoring platform is successful (should appear only if the
inverter is connected to the server).
Status: Displays OK if the inverter established successful connection and communication with the
specified server port/device (LAN, RS485, Wi-Fi or ZigBee Plug-in).
xxxxxxxx: Eight-bit Ethernet communication connection status: A string of 1s and 0s is displayed. 1
indicates OK, 0 indicates an error. F or a list of the possible errors and how to troubleshoot them, refer
to Communication T roubleshooting on page 92.
Error
message, according to failure. Refer to http://www.solaredge.com/sites/default/files/se-
inverter-installation-guide-error-codes.pdfTroubleshooting on page 92.
IP Status
This screen describes the Ethernet configuration: IP, Mask, Gateway and MAC address (Media Access
Control) of the Inverter.
I P
1 9 2 . 1 6 8 . 2 . 1 1 9
M S K
2 5 5 . 2 5 5 . 2 5 5 . 0
G W
1 9 2 . 1 6 8 . 2 . 1
M A C
0 - 2 7 - 0 2 - 0 0 - 3 9 - 3 6
ZigBee Status
This screen describes the ZigBee configuration:
P A N : X X X X X
C H : X X / X X X X
M I D : X X X X
RSSI: The receive signal strength indication of the closest ZigBee in the system. L = low, M = medium, H
= high and (-) = no signal.
PAN ID: The ZigBee transceiver PAN ID (Personal Area Network Identification), the ID uniquely
represents a device in a Zigbee network.
Ch.: The ZigBee transceiver channel
ID: The ZigBee transceiver ID
MID: The Master ID of the coordinator (master) ZigBee Plug-in. This field is shown only in devices with
router (slave) ZigBee cards, and after a successful ZigBee association. If a ZigBee Plug-in is not
connected, a No ZigBee message is displayed instead of the MID field.
StorEdge Inverter Installation Guide MAN-01-00390-1.1
< S _ O K >
< O K >
M E S S A G E >
R S S I : < L >
X X
Chapter 6: User Interface
65