Immergas Victrix Tera 28 1 Instruction Booklet And Warning

Immergas Victrix Tera 28 1 Instruction Booklet And Warning

Instantaneously wall-hung boilers condensation module sealed chamber (type c) and fan assisted or open chamber (type b) and fan assisted
Hide thumbs Also See for Victrix Tera 28 1:
Table of Contents

Advertisement

VICTRIX TERA
Instruction booklet and
IE
warning
28 1 - 32 1
Installer
User
Instantaneously wall-hung boilers
Maintenance Technician
condensation module
sealed chamber (type C)
and fan assisted
or
open chamber (type B)
and fan assisted

Advertisement

Table of Contents
loading

Summary of Contents for Immergas Victrix Tera 28 1

  • Page 1 VICTRIX TERA Instruction booklet and warning 28 1 - 32 1 Installer User Instantaneously wall-hung boilers Maintenance Technician condensation module sealed chamber (type C) and fan assisted open chamber (type B) and fan assisted...
  • Page 3 Dear Customer, Our compliments for having chosen a top-quality Immergas product, able to assure well-being and safety for a long period of time. As an Immergas Customer, you can also count on a qualified after-sales service, prepared and updated to guarantee constant efficiency of your boiler. Read the following pages carefully: you will be able to draw useful suggestions regarding the correct use of the appliance.
  • Page 4: Table Of Contents

    3.9 Password-protected special functions..36 1.10 External temperature probe (Optional). 10 2.12 Decommissioning........28 3.10 Screed heater function......36 1.11 Immergas flue systems......11 3.11 Automatic vent function (dl)....36 1.12 Tables of resistance factors and equivalent 3.12 Flue installation (Fu)........36 lengths.
  • Page 5: Boiler Installation

    Do not attempt to modify or repair the The place of installation of the appliance and appliance alone. relative Immergas accessories must have suitable Failure to comply with the above implies personal features (technical and structural), such as to al- responsibility and invalidates the warranty.
  • Page 6: Main Dimensions

    2 (EN 1717:2002 or local stand- ards in force). The materials used for the central heating circuit of Immergas boilers withstand ethylene and propylene glycol based antifreeze liquids (if the mixtures are prepared perfectly). For life and possible disposal, follow the sup- plier's instructions.
  • Page 7: Installation Inside Arecessed Frame (Optional)

    1.4 INSTALLATION INSIDE A RECESSED FRAME (OPTIONAL). The boiler is designed for installation inside the Immergas recessed frame (supplied as optional). The necessary parts for this type of installation (brackets) must also be purchased separately as optional kit. To install proceed as follows:...
  • Page 8: Boiler Connection Unit

    In the event condensate is not discharged into Ensure correct gas cock connection. The gas Attention: Immergas declines all liability in the the wastewater drainage system, a condensate supply pipe must be suitably dimensioned...
  • Page 9: Electrical Connection

    2 metres from Comando Amico Remoto Remote Control Attention: Immergas S.p.A. declines any respon- the boiler. or On/Off chrono-thermostat electrical con- sibility for damage or physical injury caused by nections (Optional).
  • Page 10: External Temperature Probe (Optional)

    Immergas chrono-thermostats. The correlation between system flow temperature and external temperature is determined by the position of the central heating selector switch on...
  • Page 11: Immergas Flue Systems

    Attention: the boiler must be installed ex- using the appropriate pre-sections in the frame clusively with an original Immergas “Green to exit from its clearances. Range” inspectionable air intake system and flue gas extraction system made of plastic, with the exception of the C6 configuration, as required by the regulations in force.
  • Page 12 Resistance Equivalent length Equivalent length Equivalent length Equivalent length TYPE OF DUCT Factor in m of concentric in metres of pipe in metres of pipe in m of concentric pipe Ø 60/100 Ø 80 60 Ø pipe Ø 80/125 Intake m 7.3 Concentric pipe Ø...
  • Page 13: Outdoor Installation In Partially Protected Area

    Ø60/100 and Ø 80/125 concentric intake/ via a vertical terminal for direct exhaust (B exhaust kits. Refer to the paragraph on indoor or via an Immergas ducting system (B installation. In this configuration the upper The technical regulations in force must be cover kit guarantees additional protection for respected.
  • Page 14: Internal Installation Usinga Recessed Frame With Direct Air Intake

    1.14 INTERNAL INSTALLATION USING Separator kit installation: install the discharge A RECESSED FRAME WITH DIRECT flange on the central hole of the boiler, posi- AIR INTAKE tioning the relative gasket with the circular • Configuration type B, open chamber and fan projections downwards in contact with the assisted.
  • Page 15: Concentric Horizontal Kit Installation

    For installation case the special extensions must be requested. with frontal outlet, one must use the fixing plate Immergas also provides a Ø 60/100 simplified and a concentric bend coupling in order to ensure terminal, which in combination with its ex-...
  • Page 16: Concentric Vertical Kit Installation

    1.16 CONCENTRIC VERTICAL KIT Ø 60/100 (3) concentric terminal pipe with the (4), shaping it to ensure that rainwater runs off. INSTALLATION. male side (5) (smooth) into the flange (2) up to Position the fixed half-shell (5) on the aluminium Type C configuration, sealed chamber and the end stop;...
  • Page 17: Separator Kit Installation

    1.17 SEPARATOR KIT INSTALLATION. (5) up to the end stop; making sure that the Type C configuration, sealed chamber and internal wall sealing plate has been fitted, this fan assisted. will ensure sealing and joining of the elements making up the kit. Separator kit Ø...
  • Page 18: Adaptor C9 Kit Installation

    To determine the C flue system in config- urations other than that described (Fig. 30) This kit allows an Immergas boiler to be installed and caps (6) on the wall and assemble the flue in "C " configuration, with combustion air intake system to the ducting system.
  • Page 19: Ducting Of Flues Or Technical Slots

    For B configurations, exhaust is only allowed into individual chimney or directly into the external Immergas ducting system. The Ø 60 rigid, Ø - The max. possible length of the Ø 80 flexible atmosphere via a relevant terminal. The multiple 80 flexible and Ø80 rigid “Green Range”...
  • Page 20: Flues, Chimneys And Chimney Caps

    1.22 FLUES, CHIMNEYS AND CHIMNEY - For filling, you are not allowed to use water 1.25 FILLING THE CONDENSATE DRAIN CAPS. TRAP. softened with the use of ionic-exchange resins The flues, chimneys and chimney caps for the or distilled water. On first lighting of the boiler, flue gas may come evacuation of combustion products must be in out the condensate drain;...
  • Page 21: Gas System Start-Up

    1.26 GAS SYSTEM START-UP. 1.28 CIRCULATION PUMP. To start up the system, refer to the technical The boilers are supplied with a variable speed standard in force: circulator pump. In particular, for new gas systems: In the central heating mode, the following op- - open windows and doors;...
  • Page 22 Total head available to the system. Victrix Tera 28 1 Flow rate (l/h) A+B = Head available with by-pass closed B = Head available with by-pass open C+D = Power absorbed by the pump with by-pass open (dotted area) D = Power absorbed by the pump with by-pass closed (dotted area)
  • Page 23: Boiler Components

    1.29 BOILER COMPONENTS. Key: 9 - Gas nozzle 18 - Return probe 1 - System expansion vessel 10 - Gas valve 19 - System pressure switch 2 - Burner 11 - DHW heat exchanger 20 - Air vent valve 3 - Ignition/detection electrode 12 - System draining valve 21 - Boiler pump 4 - Air intake pipe...
  • Page 24: Use And Maintenance Instructions

    USE AND MAINTENANCE the appliance and on completion of operations At the end of its service life, the appliance must ensure that a qualified technician checks efficien- not be disposed of like normal household waste INSTRUCTIONS. cy of the ducting or other devices. nor abandoned in the environment, but must 2.1 CLEANING AND MAINTENANCE.
  • Page 25: Using The Boiler

    2.4 USING THE BOILER. • Operation with optional external probe Before ignition make sure the heating system ). In the case of a system with optional is filled with water and that the manometer (8) external probe, the boiler flow temperature indicates a pressure of 1 ÷...
  • Page 26: Fault And Anomaly Signals

    (38). cycle. (1) (1) If the block or anomaly persists, contact an authorised company (e.g. Immergas Technical After-Sales Service). (2) The anomaly can only be verified in the list of errors in the “Information” menu...
  • Page 27 The boiler does not start (1) detected drift (1) If the block or anomaly persists, contact an authorised company (e.g. Immergas Technical After-Sales Service). (2) The anomaly can only be verified in the list of errors in the “Information” menu...
  • Page 28: Information Menu

    If pressure falls below 1 bar (with the circuit cold), of the Immergas Anti-freeze Kit in the boiler. In restore normal pressure via the cock located at the the case of prolonged inactivity (second case), bottom of the boiler (Part.
  • Page 29: Boiler Start-Up (Initial Check)

    BOILER START-UP (INI- - check the proper calibration of the number of - ensure production of domestic hot water; fan revolutions; TIAL CHECK). - ensure sealing efficiency of water circuits; - check the CO in the combustion products at - check ventilation and/or aeration of the instal- To commission the boiler: maximum and minimum flow rate;...
  • Page 30: Wiring Diagram

    3.2 WIRING DIAGRAM. 230 Vac 50Hz supply voltage Key: M1 - Boiler pump Colour code key: B1 - Flow probe M20 - Fan BK - Black B2 - Domestic hot water probe M30 - Three-way motor stepper BL - Blue B4 - External probe (optional) S4 - Domestic hot water flow switch BR - Brown...
  • Page 31: Troubleshooting

    3.3 TROUBLESHOOTING The gas conversion operation must be carried Victrix Tera 32 1 N.B.: maintenance interventions must be carried out by an authorised company (e.g. Immergas ∆P > 200 Pa out by an authorised company (e.g. Immergas After-Sales Technical Assistance Service).
  • Page 32: Checks Following Conversion To Another Type Of Gas

    (does not detach from burner); N.B.: all boiler adjustment operations must be carried out by a qualified technician (e.g. Im- mergas After-Sales Assistance). Victrix Tera 28 1 at maximum at minimum output output...
  • Page 33: Programming The P.c.b

    3.8 PROGRAMMING THE P.C.B. button “ ”. The boiler is prepared for possible programming of several operation parameters. By modifying these parameters as described below, the boiler can be adapted according to specific needs. To access the programming phase, press and hold the buttons “...
  • Page 34 Customised Parameter Description Range Default Parameter value Max DHW Defines the maximum heat output percentage of the boiler during the D.H.W. 0 - 100 % 100 % output phase compared to the maximum heat output available Min CH output Defines in percentage the minimum output in central heating mode 0 - P2 Victrix Tera 28 1...
  • Page 35 0 Fixed: the switch-off temperature is fixed at the maximum value regardless DHW thermostat 0 ÷ 1 of the value set on the control panel. 1 Correlated: the boiler switches off according to the temperature set. Victrix Tera 28 1 Customised Parameter Description Range...
  • Page 36: Password-Protected Special Functions

    3.12 FLUE INSTALLATION (FU). 3.9 PASSWORD-PROTECTED SPECIAL To activate the “Flue” function access the special FUNCTIONS. functions as described in Paragraph 3.9 and Attention: the boiler is equipped with some special select the “FU” function. functions, access to which is granted if this is in stand-by ( Attention: Before performing the test, ensure that the condensate drain trap has been filled...
  • Page 37: Chimney Sweep Function

    3.14 "CHIMNEY SWEEP FUNCTION". Note: in order for the boiler to work properly, the - Check that the system static pressure (with When activated, this function forces the boiler temperature selected on the mixing valve must system cold and after refilling the system by to variable output for 15 minutes.
  • Page 38: Casing Removal

    3.20 CASING REMOVAL. • Front panel (Fig. 53). • Front (Fig. 54). To facilitate boiler maintenance the casing can 4) Remove the cover caps (c) and loosen screws 6) Loosen the two screws (g). be completely removed as follows: (d). 7) Pull the front (f) slightly towards you.
  • Page 39 • Control panel (Fig. 55). • Sides (Fig. 56). 9) Press the hooks on the side of the control 11) Loosen screws (k) of side fastening (j). panel (i). 12) Remove the sides by extracting them from 10) Tilt the control panel (i) towards you. their rear seat (Ref.
  • Page 40: Variable Heat Output

    N.B.: the power data in the table has been ob- below a temperature of 15°C and at a pressure tained with intake-exhaust pipe measuring 0.5 m of 1013 mbar. Victrix Tera 28 1. METHANE (G20) PROPANE (G31) HEAT POWER HEAT POWER...
  • Page 41: Combustion Parameters

    3.22 COMBUSTION PARAMETERS. Supply pressure mbar (mm H 20 (204) 37 (377) Victrix Tera 28 1 Gas nozzle diameter 5.00 3.80 Flue flow rate at nominal heat output kg/h Flue flow rate at min heat output kg/h at Nom./Min. Q.
  • Page 42: Technical Data

    3.23 TECHNICAL DATA. Victrix Tera 28 1 Victrix Tera 32 1 Domestic hot water nominal heat input kW (kcal/h) 28,8 (24773) 32.6 (28047) Central heating nominal heat input kW (kcal/h) 24,6 (21194) 28.6 (24588) Minimum heat input kW (kcal/h) 4,5 (3862) 5.1 (4413)
  • Page 43: Key For Data Nameplate

    3.24 KEY FOR DATA NAMEPLATE. Code Md Sr N° Code PIN Type n min. max. n min. n max. Class CONDENSING N.B.: the technical data is provided on the data plate on the boiler Model Code Md Model code Sr N° Serial Number Check Code PIN...
  • Page 44: Technical Parameters For Combination Boilers (In Compliance With Regulation 813/2013)

    Contact information IMMERGAS S.p.A. VIA CISA LIGURE, 95 - 42041 BRESCELLO (RE) ITALY (*) High temperature mode means 60°C on return and 80°C on flow. (**) Low temperature mode for condensation Boilers means 30°C , for low temperature boilers 37°C and for other appliances 50°C of return temper- ature.
  • Page 45: Product Fiche (In Compliance With Regulation 811/2013)

    3.26 PRODUCT FICHE (IN COMPLIANCE WITH REGULATION 811/2013). Victrix Tera 28 1 Victrix Tera 32 1 VICTRIX TERA 28 1 VICTRIX TERA 32 1 Parameter value Parameter value Annual energy consumption for the heat- Annual energy consumption for the heat-...
  • Page 46: Parameters For Filling The Package Fiche

    3.27 PARAMETERS FOR FILLING THE to make up the assembly (e.g. solar devices, in- PACKAGE FICHE. tegration heat pumps, temperature controllers). In case you should wish to install an assembly, Use board Fig. 59 for “assemblies” related to the starting from the Victrix Tera (28 1 or 32 1) central heating mode (e.g.: boiler + temperature boiler, use the assembly charts in Fig.
  • Page 47 Parameters for filling in the assembly chart. Parameter Victrix Tera 28 1 Victrix Tera 32 1 ‘I’ ‘II’ ‘III’ 1.11 0,95 ‘IV’ 0.44 0,37 * to be established by means of table 5 of Regulation 811/2013 in case of “assembly” including a heat pump to integrate the boiler.
  • Page 48 Facsimile for filling in domestic hot water production system package fiche. Water heating energy efficiency of combination boiler ‘I’ Stated load profile: Solar contribution From the board of the solar device Auxiliary electricity ( 1,1 x ‘I’ 10 % ) ‘II’...
  • Page 49 Parameters for filling in DHW package assembly chart. Parameter Victrix Tera 28 1 Victrix Tera 32 1 ‘I’ ‘II’ ‘III’ * to be determined according to Regulation 811/2013 and transient calculation methods as per Notice of the European Community no. 207/2014.
  • Page 52 Follow us Immergas Italia immergas.com Immergas S.p.A. 42041 Brescello (RE) - Italy Tel. 0522.689011 Fax 0522.680617 Certified company ISO 9001...

This manual is also suitable for:

Victrix tera 32 1

Table of Contents