General Inverter Error Codes
Error #
Error # Three
Single Phase
Phase
61/62/63,
32, 41
67/68/69
34
79/80/81
35
82/83/84
36
72/74/75
40
N/A
43
N/A
44
44
46
N/A
103, 119
N/A
49
N/A
78
91/92/93 (TZ
L1/L2/L3),
N/A
96/97/98 (Iac
L1/L2/L3
Max).
N/A
99-101
N/A
105
N/A
124
86
LCD
Message
If permitted by local authorities, change the grid protection
o
values. Refer to
http://www.solaredge.com/files/pdfs/viewing_grid_
protection_values.pdf
AC Voltage Too
Low
Verify that the inverter is set to the correct country.
o
Consult the grid operator.
o
AC Freq Too
If permitted by local authorities, change the grid protection
o
High (Line
values. Refer to
1/2/3)
http://www.solaredge.com/files/pdfs/viewing_grid_
protection_values.pdf
AC Freq Too
Low (Line 1/2/3)
DC Injection
Contact SolarEdge support.
(Line 1/2/3)
AC grid voltage malfunction. When AC voltage returns the
Islanding
inverter should restart after the reconnection time.
If the problem persists, consult with the grid operator.
Internal HW
Contact SolarEdge support.
Error
No Country
Select the country, as described in Country and Grid on page
Selected
45.
Phase
Select Power Control è Phase Balance è Disable.
Unbalance
UDC Min / DC
Turn the inverter OFF and ON. If the fault persists, contact
Voltage Too
SolarEdge support.
Low
Communication
Contact SolarEdge support.
Error
Grid Sync Error
Contact SolarEdge support.
AC Over
Current Line
Contact SolarEdge support.
1/2/3
AC Voltage Too
Turn the inverter OFF and ON. If the fault persists, contact
High Line 1/2/3
SolarEdge support.
Temperature
Make sure the inverter is installed in a location with ambient
Too Low
temperatures within the range specified in the datasheet.
Ground Current Contact SolarEdge support.
SolarEdge-StorEdge Installation Guide MAN-01-00262-1.0
Cause and Troubleshooting