SolarEdge StorEdge Installation Manual page 86

Hide thumbs Also See for StorEdge:
Table of Contents

Advertisement

Error #
Error # Three
Single Phase
Phase
15
102
16
123
17
104
24
N/A
25
121
26
122
95, 106, 120,
27, 153
125, 126
28
N/A
29-30
N/A
31, 33
64/65/66
SolarEdge-StorEdge Installation Guide MAN-01-00262-1.0
LCD
Message
Refer to the AC Wiring Application Note
o
http://www.solaredge.us/files/pdfs/application-note-
recommended-wiring.pdf
The SolarEdge system normally eliminates DC overvoltage
errors. If the fault persists:
Turn OFF the inverter ON/OFF switch. If after five
o
minutes, the LCD panel does not show a low safety
voltage (1V per optimizer), check which string is
DC Voltage Too
malfunctioning and recheck its connections to the
High
inverter.
Proceed according to Power Optimizer Troubleshooting
o
on page 88
Re-commission all inverters in the site, as described in
o
Commissioning the Installation on page 55
Hardware Error
Contact SolarEdge Support.
Temperature
Verify proper inverter clearances.
o
Too High
Make sure the heat-sink fins are clean and unobstructed.
o
Faulty Temp.
Broken or unconnected temperature sensor. Contact
Sensor
SolarEdge Support.
Check the PV installation for isolation problems and
o
ground leakage.
Only a certified PV installer must fix the faulty string
o
Isolation Fault
before connecting it to the inverter.
Refer to
o
isolation_fault_troubleshooting.pdf
Faulty AC
Disconnect inverter from AC grid.
o
Relay
Contact SolarEdge Support.
o
Hardware Error
Contact SolarEdge support.
RCD Sensor
Contact SolarEdge support.
Error
Check the grid connection.
o
Check the GND connection.
o
Phase Balance
Check the L1, L2 and Neutral connections.
o
Error
Verify symmetric load between L1 and L2.
o
Consult the local grid authority.
o
Verify that the inverter is set to the correct country.
o
Turn OFF the inverters in the site and verify AC grid
o
AC Voltage Too
voltage.
High (Line
If the inverter is located far from the connection point to
o
1/2/3)
the grid, use a larger gauge AC wire.
Consult the grid operator.
o
Appendix A: Troubleshooting
Cause and Troubleshooting
www.solaredge.us/files/pdfs/application_note_