to display the Meter status screen:
I m p o r t
S t a t u s :
T o t a l [ W h ] : X X X X X X X
 3.  Press the inverter LCD light button to display the Smart Energy Management and the battery status 
screens, and check that: 
 
The State the battery is Discharging (assuming the load consumption > PV production and AC limit 
o
of inverter > PV  production) - The loads are powered by the PV and the battery; if the test is 
performed at night, the loads are powered only by the battery.
 
The PWR value is greater than 0 
o
 
o
B S N :
S O E : 8 9 %
T o t a l :
S t a t e :
S i t e
S i t e
S i t e
S e l f - c o n s u m e :
 4.  While the modules are exposed to sunlight , verify that the battery is operating properly: 
 a.  Minimize the house load consumption by turning off all the load circuit breakers, except for the 
inverter.
 b.  Press the external LCD light button to display the battery status screen, and check that: 
 
The battery State is: Charging 
l
 
The SOE percentage is increasing
l
 
The PWR value is greater than 0 
l
B S N :
S O E : 8 9 %
T o t a l :
S t a t e :
To check Backup:
 1.  Disconnect the AC power   b y shutting off the AC at the main distribution panel. The inverter should 
disconnect from the grid, and continue supplying power to the backed-up loads.
Switching to Backup mode takes a few seconds. The LCD screen will show tha Backup mode is ON:
V a c [ V ]
2 4 0 . 7
P _ O K :
B a c k u p
SolarEdge-StorEdge Installation Guide MAN-01-00262-1.0
M e t e r
< O K >
X X X X X X X X X
I D : 2 4
W W W W W
P W R :
< X > W h
D i s c h a r g i n g
L i m i t :
7 . 0 k W
P r o d :
1 0 . 0 k W
E x p o r t :
4 . 0 k W
6 . 0 k W
X X X X X X X X X
I D : 2 4
W W W W W
P W R :
< x > W h
C h a r g i n g
V d c [ V ]
P a c [ W ]
3 7 1 . 9
2 3 4 9 . 3
X X X / Y Y Y
< S _ O K >
M o d e
2 W
2 W
O N
Chapter 9: System Configuration