Configuring StorEdge Application

This section describes the StorEdge applications and how to configure the system per application.

Maximize Self-consumption

In this mode, the battery is automatically charged and discharged to meet consumption needs. This 
application requires connection to a meter.
The battery has two states:
 
OFF – the battery is in standby
l
 
ON – the battery is controlled for maximized self-consumption
l
Battery OFF periods can be configured to extend battery lifetime by minimizing the number of shallow 
discharges (for example at nighttime or during the winter). 

Profile Programming (for time of use arbitrage)

In this mode, the StorEdge system operates according to a configured charge/ discharge profile. This 
application requires connection to a meter. This   a pplication is covered in a separate application note 
available at http://www.solaredge.com/files/pdfs/StorEdge_TOU_profile_programming.pdf.
This application can be used whether or not PV modules are installed at the site.

Backup Power

The produced power is stored in the battery to be used during power outages. The StorEdge inverter 
senses the grid voltage, and when it is down it automatically switches to Backup mode, disconnecting  
from the grid and supplying   p ower to the backed-up loads. This application requires connection to the 
SolarEdge Auto-transformer and a backed-up loads panel. 
This application can be used in one of two ways:
 
Backup-only – energy stored in the battery is discharged for backup power only
l
 
Backup with Smart Energy Management – use some of the battery energy for backup power and the 
l
rest for MSC or TOU applications.
The Backup application can be used whether or not PV modules are installed at the site.

System Configuration

To access the Energy Control menu:
 1.  Enter Setup mode, scroll down to the Power Control menu and select it. A menu similar to the 
following is displayed:
G r i d
E n e r g y
R R C R
R e a c t i v e
A c t i v e
P h a s e
W a k e u p
P ( f )
A d v a n c e d
L o a d
SolarEdge-StorEdge Installation Guide MAN-01-00262-1.0
C o n t r o l
< E n >
M a n a g e r
C o n f .
P w r
C o n f .
P w r
C o n f .
B a l a n c e
< D i s >
C o n f .
D e f a u l t s
Chapter 9: System Configuration
65