Step 1: Activating the System
3. Activate the inverter according to the activation instructions supplied in the inverter package:
a. Verify that the card S/N matches the inverter S/N.
b. Insert the card into the slot marked "CARD" on the communication board.
c. Turn AC ON.
d. LCD shows: Running Script... è Done!
e. If LCD shows: Script error, contact SolarEdge Support.
4. Verify that the inverter is configured to the proper country: Press the LCD light button until reaching
the ID status screen:
I D :
# # # # # # # #
D S P 1 / 2 : 1 . 0 2 1 0 / 1 . 0 0 3 4
C P U : 0 0 0 3 . 1 4 x x
C o u n t r y : U S A 1
5. If required, perform the following additional steps before closing the inverter cover:
Country settings or inverter configuration using the internal LCD user buttons – refer to Country
l
and Grid on page 45.
Communication options connection – refer to Setting Up Communication to the Monitoring Portal
l
on page 71.
StorEdge application configuration - refer to System Configuration on page 62.
l
6. Close the inverter cover b y tightening the screws with a torque of 9.0 N*m/ 6.6 lb*ft. For proper
sealing, first tighten the corner screws and then the two central screws. The following figure
illustrates recommended order:
7. Make sure the AC Bypass switch is switched to the left (position 1).
56
Figure 27: Activation card
# #
Figure 28: Tightening order of the screws
SolarEdge-StorEdge Installation Guide MAN-01-00262-1.0