Smart Energy Management Status; Power Control Status - SolarEdge StorEdge Installation Manual

Hide thumbs Also See for StorEdge:
Table of Contents

Advertisement

 
##: The total number of slaves detected on the specific port
l
 
Dev: The type of device that was configured to a specific port (based on the port's functionality), as 
l
follows:
 
SE: SolarEdge device (default)
o
 
DM: Revenue meter
o
 
LGR: Non-SolarEdge logger
o
 
PROT: The protocol type to which the port is set:
l
 
For a SolarEdge device:
o
 
S: SolarEdge slave
n
 
M: SolarEdge master
n
 
P2P: ZigBee point-to-point
n
 
MPM: ZigBee multipoint master (for the SolarEdge ZigBee home gateway)
n
 
MPS: ZigBee multipoint slave (for a ZigBee router module)
n
 
For electricity meters,   r efer to the application note - Connecting an Electricity Meter to SolarEdge 
o
Devices at http://www.solaredge.us/files/pdfs/connecting-revenue-grade-meter-to-solaredge-
devices.pdf.
 
SS: SunSpec - for a non-SolarEdge logger (monitoring and control)
o

Smart Energy Management Status

This screen is displayed only when Smart Energy Management is enabled. The screen shows energy details 
of the site:
S i t e
L i m i t :
S i t e
P r o d :
S i t e
E x p o r t :
S e l f - c o n s u m e :
 
Site Limit: The limit that was defined for the site
l
 
Site Prod: The power produced by the site
l
 
Site Feed: The power that is fed into the grid
l
 
Self-consume: The PV power consumed by the site
l

Power Control Status

This screen is displayed only when Power Control is enabled (available from communication board (CPU) 
firmware version 2.7xx/3.7xx and later).
P W R
C T R L :
P W R
L i m i t :
C o s P h i :
P o w e r
P r o d :
 
PWR CTRL: The power control status: 
l
 
REMOTE - Communication with the RRCR or smart energy manager is confirmed/validated. 
o
 
LOCAL - The power is controlled locally (e.g. by a fixed limit), or this inverter limits the PV power 
o
production to its relative portion of the feed-in power limit, as a result of disconnected 
communication with the smart energy manager. If this status appears, check the communication 
to the smart energy manager or the communication to the meter. 
SolarEdge-StorEdge Installation Guide MAN-01-00262-1.0
7 . 0 k W
1 0 . 0 k W
4 . 0 k W
6 . 0 k W
R E M O T E
1 0 . 0 4
k W
0 . 9
7 0 0 0 W
Chapter 7: User Interface
53

Advertisement

Table of Contents
loading

Table of Contents