Energy Meter Status

Energy Meter Status
Displays the total energy produced during the last day, month, year and since inverter installation.
D a y [ W h ] :
M o n t h [ K W h ] :
Y e a r [ K W h ] :
T o t a l [ K W h ] :
If   a  meter is connected to the inverter, the following status screen, showing the total energy reading, is 
displayed instead of the above screen. The following is an example of a production meter status:
P r o d u c t i o n
S t a t u s :
< E r r o r
T o t a l [ W h ] : X X X X X X X
If the meter is set to Export +Import, there are two status screens, with the first line displaying: 
"Export Meter" and "Import Meter".
 
Status: Displays OK if the meter is communicating with the communication board.
l
 
<Error message>: If there is a meter error, it is displayed in this line.
l
 
Total (Wh): The energy read by the meter. The value displayed in this line depends on the meter type 
l
connected to the inverter and its location:
 
If a bidirectional meter is connected at the consumption point, this value is the consumed energy.
o
 
If the meter is installed at the production connection point, this value is the energy produced by 
o
the site.
 
If the meter is installed at the grid connection point, this value is the energy exported to the grid.
o
If the inverter is connected to the SolarEdge server, this value will also be displayed in the monitoring 
portal.
NOTE
This data is accumulated according to an internal real-time clock.

Telemetry Status

This screen displays the last power optimizer telemetry received. The display changes as each power 
optimizer sends its telemetry.
In order to verify proper installation, the installer may view the Telemetry window for some time in order 
to observe the power optimizers' report process.
M o d u l e :
E n e r g y [ W h ] : 0
V d c _ O [ V ] :
V d c _ I [ V ] :
 
Module#: Power optimizer serial number
l
 
Energy: power optimizer energy
l
 
Vdc_O: Power optimizer output voltage
l
 
Vdc_I: Power optimizer input voltage (module voltage)
l
50
0 . 0
0 . 0
0 . 0
0 . 0
M e t e r
< O K >
M e s s a g e >
0 0 0 C 1 E D 9 - 0 3
0 . 5
2 9 . 5
SolarEdge-StorEdge Installation Guide MAN-01-00262-1.0