Maintenance

Maintenance
Select Maintenance to set the following options:
D a t e
a n d
R e s e t
C o u n t e r s
F a c t o r y
S W
U p g r a d e
A F C I
< E n >
D i a g n o s t i c s
S t a n d b y
G r i d
P r o t e c t i o n
O p t i m i z e r
 
Date and Time: Set the internal real-time clock. If connected to the SolarEdge monitoring portal, the 
l
date and time are set automatically and only time zone should be set.
 
Reset Counters: Resets the accumulated energy counters that are sent to the SolarEdge monitoring 
l
portal
 
Factory Reset: Performs a general reset to the   d efault device settings.
l
 
SW Upgrade SD-Card: Perform a software upgrade using an SD card.
l
 
Diagnostics: Displays the Isolation Status and optimizers status screens. Refer to 
l
http://www.solaredge.us/files/pdfs/application_note_isolation_fault_troubleshooting.pdf.
 
AFCI: Enables or disables arc-fault self-test.
l
 
Manual AFCI Test: Accessible from the LCD Light button menus only. Starts a self-test for arc 
l
detection. 
 
Standby Mode: Enables/disables Standby Mode - for remote commissioning.
l
 
Grid Protection: Available in specific countries. Enables viewing and setting grid protection values. 
l
Refer to http://www.solaredge.com/files/pdfs/viewing_grid_protection_values.pdf.
 
Optimizer Conf.: Accessible from the LCD Light button menus only (the inverter ON/OFF swittch 
l
must be ON). Enables the Rapid Shutdown feature when a kit is installed in the inverter. 

Information

Select Information to display the following options:
V e r s i o n s
E r r o r
L o g
W a r n i n g
H a r d w a r e
 
Versions: Displays inverter firmware versions:
l
 
ID: The inverter ID.
o
 
DSP 1/2: The DSP digital control board firmware version
o
 
CPU: The communication board firmware version
o
NOTE
Please have these numbers ready when you contact SolarEdge Support.
 
Error Log: Displays the last five errors.
l
 
Warning Log: Displays the last five warnings.