SolarEdge StorEdge Installation Manual page 32

Hide thumbs Also See for StorEdge:
Table of Contents

Advertisement

Recommended cable type
(min-max AWG)
Control and monitoring
5-wire shielded twisted pair cable
24 AWG (16-24AWG), 600V
insulated.
A CAT5 600V insulated can also be
used.
 
1 Must be twisted pair
2 Must be twisted pair
SolarEdge-StorEdge Installation Guide MAN-01-00262-1.0
StorEdge
Connection
Tesla battery
Unit
connection
connection
5-pin
communication port
communication
1 (located closer to
terminal block:
the DIP switches):
En (Enable)
ENABLE
V+
LOGIC +
G (RS485)
LOGIC -
1
B- (RS485)
COM LO
1
A+ (RS485)
COM HI
Modbus DIP switch
setting:
S2, S6: Left
o
S1, S5: DOWN
o
S3, S4: UP
o
ID DIP switch
setting: All (1,2,3) to
the right (0 position)
Chapter 6: StorEdge Inverter Connections
Connection method
Press the protrusion at the top of the
terminal block to open the connection
hole, insert the wire and release to
spring back and clamp the wire.
2
2
Refer to Figure 19 and Figure 20.