Inverter Configuration - Setup Mode - SolarEdge SE5000H-US Installation Manual

Hd-wave
Hide thumbs Also See for SE5000H-US:
Table of Contents

Advertisement

Inverter Configuration – Setup Mode
Inverter Configuration – Setup Mode
After inverter installation, an installer may perform basic system configuration. Configuration is done 
when the inverter is in Setup mode.
To enter Setup mode:
 1.  Turn the inverter ON/OFF switch to OFF (AC remains ON). 
WARNING!
If the inverter was operating properly (power was produced by the power optimizers), the
following message is displayed.
This message is displayed until the DC voltage is safe (50V). Do not open the cover until the
voltage is safe or until at least five minutes have passed.
La tension de sécurité par défault est de 50V.
 
Ne pas ouvrir le couvercle ou les connecteurs DC jusqu'à ce que la tension soit affichée comme
sécurisé ou jusqu'à ce que cinq minutes au moins se soient écoulées.
 2.  Press the OK button for at least 5 seconds. The following message is displayed:
P l e a s e
P a s s w o r d
* * * * * * * *
 3.  Press the Up, Down and OK buttons (Up=1, Down=2, OK=3) for entering the Setup mode password:  
pq OK pqOK pq (12312312). 
C o u n t r y
L a n g u a g e
C o m m u n i c a t i o n
P o w e r
C o n t r o l
D i s p l a y
M a i n t e n a n c e
I n f o r m a t i o n
The   i nverter is now in Setup mode and all its LEDs are lit. The   i nverter automatically exits Setup mode if no 
buttons are pressed for more than 2 minutes.
 
34
D C
V O L T A G E
D O
N O T
D I S C O N N E C T
V D C :
7 2 . 0
e n t e r
< U S A + >
< E n g >
SolarEdge HD-Wave Inverter Installation Guide MAN-01-00306-1.0
N O T
S A F E

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents