SC Code Descriptions
6.2.6 SC6XX: DEVICE COMMUNICATION
SC No.
Level
622-00
B
SC No.
Level
623-00
B
SM
Error Name/Error Condition/Major Cause/Solution
2nd tray communication error
An error occurs during the line connection between the
mainframe and the optional PFU (2nd tray).
A communication error report is received between the
mainframe and the optional PFU (2nd tray) is received.
The 2nd paper tray's main board defective
MPU defective
2nd tray and the machine are not connected correctly.
Reconnect the 2nd tray connection cable.
Replace MPU.
Replace the 2nd tray.
Error Name/Error Condition/Major Cause/Solution
3rd tray communication error
An error occurs during the line connection between the
mainframe and the optional PFU (3rd tray).
A communication error report is received between the
mainframe and the optional PFU (3rd tray).
2nd tray main board defective
3rd tray main board defective
2nd tray and 3rd tray not connected correctly
Reconnect the 2nd tray and 3rd tray connection cable.
Replace the 3rd tray.