SC Code Descriptions
6.2 SC CODE DESCRIPTIONS
6.2.1 SC1XX: SCANNING
SC No.
Level
101-01
B
SC No.
Level
102-00
B
SM
Error Name/Error Condition/Major Cause/Solution
Lamp error (scanning)
The white level peak did not reach the prescribed threshold
when the white plate was scanned.
CIS defective
MPU defective
Harness defective
Condensation in the scanner unit
CIS dirty or positioned incorrectly
White plate dirty or positioned incorrectly
1.
Perform the following operations.
Reconnect the harness of the CIS.
Reattach or clean the CIS.
Reattach or clean the white plate.
2.
Replace the following parts.
Replace the CIS.
Replace the MPU.
Replace the harness of the CIS.
Error Name/Error Condition/Major Cause/Solution
LED light adjustment error
The white peak exceeded the prescribed threshold when the
white plate was scanned after a specified number of
adjustments.
CIS defective.
MPU defective
Harness defective