Adjustment after Replacement
Tray
Duplex: Thick
2.
Check the side-to-side registration [B] for each paper feed station, and adjust them
using SP1-002.
Tray
By-pass
Tray Main1
Tray Bank1
Tray Bank2
Duplex
Main Scan Magnification
Use an S5S test chart to perform the following adjustments.
1.
Check the magnification, and adjust the magnification using SP2-102-001
(Magnification Adjustment Main Scan) if necessary. The specification is ± 0.5%.
SM
SP No.
SP1-001-015
SP No.
SP1-002-001
SP1-002-002
SP1-002-004
SP1-002-005
SP1-002-006
4-70
Threshold
Threshold
2 ±1.5 mm
D245/D246/D247