Battery Troubleshooting - SolarEdge SE7600A-US Installation Manual

Storedge solution with backup
Hide thumbs Also See for SE7600A-US:
Table of Contents

Advertisement

 
White CT wire is connected to L1 white 
o
 
Black CT wire is connected to L1 black 
o
 
CT direction is towards the grid and the green power LEDs are ON. If the LEDs are not green indicating 
l
import power - the CTs are reversed.

Battery Troubleshooting

The State line in the battery status screen should display one of the following: Charging, Discharging, Idle, 
Off, Init.:
B S N :
X X X X X X X X X
S O E :
8 9 %
T o t a l :
S t a t e :
 
If error code 3x6B (or Error 186) - Battery Comm. Error appears, the battery communication is 
l
disconnected. Check the following:
 
The RS485 control connection to the battery
o
 
The communication DIP switches settings on the battery      
o
 
The ID DIP switches setting on the battery 
o
 
If the state Idle is displayed instead of Charging/Discharging, check the following:
l
 
The system configuration
o
 
The DC connection
o
 
The LEDs in the Connection Unit - refer to Connection Unit LEDs on page 97
o
 
If Battery Internal Fault is displayed, refer to the battery documentation supplied with it. The 
l
following is an example fault screen.
B a t t e r y
F a u l t
< x x x x >
Fault # - according to battery
ID - The Modbus ID of the battery
<xxx> - text
SolarEdge-StorEdge Installation Guide MAN-01-00262-1.3
Figure 43: Meter with CTs
I D : 1 5
W W W W
P W R :
2 W
< x > W h
C h a r g i n g
I n t e r n a l
< # > ( I D :
1 5 )
Appendix A: Troubleshooting
95

Advertisement

Table of Contents
loading

This manual is also suitable for:

Seauto-tx-5000