SolarEdge SE7600A-US Installation Manual page 85

Storedge solution with backup
Hide thumbs Also See for SE7600A-US:
Table of Contents

Advertisement

 3.  Select Communication è RS485-1 Conf è Device Type è Multi Devices. A list of devices is 
displayed.
D e v i c e
M e t e r
M e t e r
M e t e r
B a t t e r y
B a t t e r y
If an RGM is installed, it is pre-configured to Meter 1:
D e v i c e
M e t e r
M e t e r
M e t e r
B a t t e r y
B a t t e r y
 4.  Select Meter 2. The meter configuration screen is displayed (SolarEdge meters are pre-configured to 
Device ID 2):
D e v i c e
P r o t o c o l
D e v i c e
C T
R a t i n g
M e t e r
T o p o l o g y
 5.  Configure the meter:
 a.  Select Device Type è Revenue Meter
 b.  Select Protocol è WattNode
 c.  Verify that Device ID is set to  2.
 d.  Set the CT value that appears on the CT label: CT Rating è <xxxxA>. 
If CT resets to 0, check the communication as described in step b of verify the connection:below.
 e.  For a meter installed at the grid connection point select Meter Func.è Export+Import.
E x p o r t + I m p o r t
E x p o r t
C o n s u m p t i o n
P r o d u c t i o n
E x t .
I m p o r t
N o n e
 f.  The selected option is displayed in the RS485 Conf screen as <E+I>.
 g.  Select the grid Topology (WYE or Delta).
SolarEdge-StorEdge Installation Guide MAN-01-00262-1.3
T y p e
< M L T >
1
< - - - >
2
< - - - >
3
< - - - >
1
< - - - >
2
< - - - >
T y p e
< M L T >
1
< W N , 1 >
2
< - - - >
3
< - - - >
1
< - - - >
2
< - - - >
T y p e
< M T R >
< W N >
I D
< 2 >
< 0 >
F u n c .
< N o n e >
< W y e >
P r o d u c t i o n
Chapter 10: System Configuration
83