SolarEdge SE7600A-US Installation Manual page 78

Storedge solution with backup
Hide thumbs Also See for SE7600A-US:
Table of Contents

Advertisement

Creating an Ethernet (LAN) Connection
 4.  Remove the rubber fitting from the gland and insert the CAT5/6 cable through the gland and through 
the gland opening in the inverter .
 5.  Push the cable into the cut opening of the rubber fitting.
CAT5/6 standard cables have eight wires (four twisted pairs), as shown in the diagram below. Wire colors 
may differ from one cable to another. You can use either wiring standard, as long as both sides of the 
cable have the same pin-out and color-coding.
RJ45 Pin #
1
2
3
4
5
6
7
8
 6.  Use a pre-crimped cable to connect via gland #1 to the RJ45 plug on the inverter's communication 
board or, if using a spool of cable, connect as follows:
 a.  Insert the cable through gland #1.
 b.  Remove the cable's external insulation using a crimping tool or cable cutter and expose eight 
wires.
 c.  Insert the eight wires into an RJ45 connector, as described in Figure 36
 d.  Use a crimping tool to crimp the connector.
 e.  Connect the Ethernet connector to the RJ45 port on the communication board.
1 The inverter connection does not support RX/TX polarity change. Supporting crossover Ethernet cables depends on the
switch capabilities.
76
Figure 35: Rubber fitting
Wire Color
T568B
White/Orange
Orange
White/Green
Blue
White/Blue
Green
White/Brown
Brown
Figure 36: Standard cable wiring
SolarEdge-StorEdge Installation Guide MAN-01-00262-1.3
1
T568A
White/Green
Green
White/Orange
Blue
White/Blue
Orange
White/Brown
Brown
10Base-T Signal
100Base-TX Signal
Transmit+
Transmit-
Receive+
Reserved
Reserved
Received-
Reserved
Reserved