Power Control Status; Battery Status - SolarEdge SE7600A-US Installation Manual

Storedge solution with backup
Hide thumbs Also See for SE7600A-US:
Table of Contents

Advertisement

Power Control Status

Power Control Status
This screen is displayed only when Power Control is enabled (available from communication board (CPU) 
firmware version 2.7xx/3.7xx and later).
P W R
C T R L :
P W R
L i m i t :
C o s P h i :
P o w e r
P r o d :
 
PWR CTRL: The power control status: 
l
 
REMOTE - Communication with the RRCR or smart energy manager is confirmed/validated. 
o
 
LOCAL - The power is controlled locally (e.g. by a fixed limit), or this inverter limits the PV power 
o
production to its relative portion of the feed-in power limit, as a result of disconnected 
communication with the smart energy manager. If this status appears, check the communication 
to the smart energy manager or the communication to the meter. 
 
PWR Limit: The inverter maximum output power set by one of the power limiting options: 
l
 
RRCR 
o
 
Smart energy manager (Feed-in limitation) 
o
 
P(f)
o
 
P(U)
o
 
Q(U) 
o
 
Cos Phi: The ratio between active to reactive power 
l
 
Power Prod: The power produced by the inverter 
l
For more information, refer to the Power Control Application Note, available on the 
SolarEdge website at http://www.solaredge.us/files/pdfs/application_note_power_
control_configuration.pdf.

Battery Status

This screen is displayed only when the battery is configured, and shows the battery 
identification information, its charging status and power, and the operating mode.
B S N :
X X X X X X X X X
S O E :
8 9 %
T o t a l :
S t a t e :
 
BSN: Battery serial number
l
 
ID: Battery identification - should be 24 as set up above
l
 
SOE: State of Energy - the battery capacity percentage (calculated as Available Energy\Max. Energy)
l
 
PWR: The charging or discharging power (in Watts) according to the battery state (see below)
l
 
Total: The total discharged energy in Watt/hour
l
 
State: The battery status: Charging/ Discharging, Idle, Init (pre-heating) or Fault <error code>.
l
 
70
R E M O T E
1 0 . 0 4
k W
0 . 9
7 0 0 0 W
I D : 1 5
W W W W
P W R :
2 W
< x > W h
C h a r g i n g
SolarEdge-StorEdge Installation Guide MAN-01-00262-1.3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Seauto-tx-5000