Telemetry Status; Id Status - SolarEdge SE7600A-US Installation Manual

Storedge solution with backup
Hide thumbs Also See for SE7600A-US:
Table of Contents

Advertisement

Telemetry Status

 
Status: Displays OK if the meter is communicating with the communication board.
l
 
<Error message>: If there is a meter error, it is displayed in this line. Refer to Meter   T roubleshooting on 
l
page 94.
 
Power (W): Depending on the meter type connected to the inverter, this line displays the exported 
l
or imported power in Watts.
 
Energy (Wh): The total energy read by the meter, in Watt/hour. The value displayed in this line 
l
depends on the meter type connected to the inverter and its location:
 
If a bidirectional meter is connected at the consumption point, this value is the consumed energy.
o
 
If the meter is installed at the production connection point, this value is the energy produced by 
o
the site.
 
If the meter is installed at the grid connection point, this value is the energy exported to the grid.
o
If the inverter is connected to the SolarEdge server, this value will also be displayed in the monitoring 
platform.
NOTE
This data is accumulated according to an internal real-time clock.
Telemetry Status
This screen displays the last power optimizer telemetry received. The display changes as each power 
optimizer sends its telemetry.
In order to verify proper installation, the installer may view the Telemetry window for some time in order 
to observe the power optimizers' report process.
M o d u l e :
E n e r g y [ W h ] : 5 6 . 7
V d c _ O [ V ] :
V d c _ I [ V ] :
I _ i n [ A ] :
T e m p [ C ] :
 
Module: Power optimizer serial number
l
 
Energy: power optimizer energy
l
 
Vdc_O: Power optimizer output voltage
l
 
Vdc_I: Power optimizer input voltage (module voltage)
l
 
I_in: Power optimizer input current 
l
 
Temp: Power optimizer temperature
l

ID Status

This screen displays the inverter software version and the country to which the inverter is configured.
I D :
# # # # # # # #
D S P 1 / 2 : 1 . 0 2 1 0 / 1 . 0 0 3 4
C P U : 0 0 0 3 . 1 9 x x
C o u n t r y : U S A 1
 
ID: The inverter ID.
l
 
DSP 1/2: The DSP digital control board firmware version
l
66
1 0 2 8 8 0 6 3
1 B
4 0 . 0
3 8 . 3
7 . 8
2 8 . 0
# #
SolarEdge-StorEdge Installation Guide MAN-01-00262-1.3